5 POWER SUPPLY
5.1 OVERVIEW
TECHNICAL REFERENCE MANUAL DEK TQ 04/2021 51
5.1.1 Circuit Breakers
5.1.1.1 Front
CB
5
CB
4
CB
3
CB
2
CB
1
M71
F1
Circuit Breaker Current Rating Circuit Breaker Function
CB1 6A C Mains Supply to the 24V and 48V Power Supply Units
CB2 10A C Mains Supply to M71SK34 (TCM) and
M71SK35 (Internal Vacuum Pump)
CB3 6A B 24V US Supply to M71SK43 (Machine Controller)
CB4 10A B 24V US Supply to Rear Circuit Breakers
CB5 4A C 48V SW Supply to M71SK16 to 21
M71 F1 2A Mains supply to the monitor
5 POWER SUPPLY
5.1 OVERVIEW
52 TECHNICAL REFERENCE MANUAL DEK TQ 04/2021
5.1.1.2 Rear
CB1
CB2
CB3
CB4
CB5
CB6
CB7
CB8
CB9
CB10
CB11
CB12
CB13
CB14
CB15
CB16
CB17
CB18
CB19
CB20
CB21
CB22
CB23
CB24
CB25
CB26
CB27
CB28
CB29
CB30
CB31
Circuit Breaker Current Rating Supply To Connector Circuit Breaker Function
CB1 3.15A M71SK15 Fans
CB2 3.15A M71SK01 Not Used
CB3 1.5A M71SK02 Not Used
CB4 3.15A M71SK02 Not Used
CB5 1.5A M71SK02 +24V US NuMotion Logic Supply
CB6 1.5A M71SK02 Not Used
CB7 1.5A M71SK03 Not Used
CB8 3.15A M71SK03 Not Used
CB9 3.15A M71SK03 Not Used
CB10 6.3A M71SK03 Not Used
CB11 3.15A M71SK04 +24V US ESIO-1
CB12 3.15A M71SK04 +24V SW ESIO-1
CB13 1.5A M71SK04 Not Used
CB14 3.15A M71SK05 +24V US ESIO-2
CB15 3.15A M71SK05 +24V SW ESIO-2
CB16 3.15A M71SK06 +24V US ESIO-3
CB17 3.15A M71SK06 +24V SW ESIO-3
CB18 3.15A M71SK07 +24V US ESIO-4
CB19 3.15A M71SK07 +24V SW ESIO-4
CB20 3.15A M71SK08 +24V US ESIO-5
CB21 3.15A M71SK08 +24V SW ESIO-5
CB22 1.5A M71SK08 Not Used
CB23 3.15A M71SK09 +24V US ESIO-6
CB24 3.15A M71SK09 +24V SW ESIO-6
CB25 3.15A M71SK10 Not Used
CB26 3.15A M71SK10 Not Used
CB27 3.15A M71SK11 Machine Lighting
CB28 3.15A M71SK11 Not Used
CB29 3.15A M71SK12 Not Used
CB30 1.5A M71SK13 Not Used
CB31 3.15A M71SK16 to M71SK 21 +24V US Drive Logic Power To
EPM’s
5 POWER SUPPLY
5.2 POWER DISTRIBUTION
TECHNICAL REFERENCE MANUAL DEK TQ 04/2021 53
5.2 POWER DISTRIBUTION
Mains Input Power from the facility (110V to 230V ±10%, 50 to 60Hz A.C.) is routed to the Mains
Isolator Switch at the front of the machine. From the isolator, the supply is fed via an EMI line filter
and surge suppressor to the M71 Power Supply Enclosure, through a cable gland at the rear. In-
side the M71 Enclosure, the cores of the mains cable connect to the three terminal blocks: TB1
(Live), TB2 (Neutral) and TB3 (Earth/Ground). From the terminal blocks, mains power is distributed
to the following loads:
M71SK34 Temperature Control Unit (via CB2 on the front panel)
M71SK35 Internal Vacuum Pump (via CB2 on the front panel)
M71SK36 Display Monitor (via fuse M71F1 on the front panel)
24V DC PSU (via CB1 on the front panel)
48V DC PSU (via CB1 on the front panel)
The D.C. supplies from the PSU are fed to the power distribution PCB (some via the safety cir-
cuits), which mounts the enclosures rear connectors. Connected to this PCB is the PSU monitor
board, which provides a USB link to the P.C., allowing software to monitor the levels of D.C.
voltage present on the distribution PCB.