3 - 14
3.3.1 Track Errors
NOTE
Empty tracks must be set to full.
It is not possible for empty tracks to be cleared.
Click on the symbol button for
Track errors
in the
Display all track errors
menu.
Fig. 3.3.2 Track errors
l No.
The error numbers of the errors in question are displayed in this column.
l Component name (CmpName)
In this column the component name where the error occurred is displayed.
l Location (Loc.)
In this column the location corresponding to the component is displayed.
l Tr/D/T
This column displays the track, the division and the tray corresponding to the component.
F
SIPLACE 80S-20/F4/F5 User Manual 3 Placement Functions
05/99 Issue from Software Version SR.405.xx 3.3 Error
3 - 15
l Seg.
In this column the segment which was used to insert the component is displayed.
l #E
This column indicates how often (cumulative) this error has already occurred.
l Text
In this column a description is given of the fault which occurred.
3.3.1.1 Error Information
Mark a single line (highlighted with a light blue bar) and click on the
Error information
button. Call up the on-
line help for information on the selected error.
3.3.1.2 Diagnostics
Select a single line (highlighted with a light blue bar) and click on the
Diagnostics
button. The diagnostics
procedure for the error selected is started.
3 Placement Functions SIPLACE 80S-20/F4/F5 User Manual
3.3 Error 05/99 Issue from Software Version SR.405.xx
3 - 16
3.3.2 Machine Errors
Click on the symbol button for
Errors
in the
Display all machine errors
menu
.
Fig. 3.3.3 Machine errors
l No.
The error numbers of the errors in question are displayed in this column.
l Seg.
In this column the segment which was used to insert the component and where the fault occurred is dis-
played.
l DEV
In this column the pick-up side, i.e. the gantry where the fault occurred, is displayed.
l #E
This column indicates how often (cumulative) this error has already occurred.
l Text
In this column a description is given of the fault which occurred.
F