80S-2080F480F5.pdf - 第210页

4 Single Functions SIPLACE 80S-20/F4/F5 Us er Manual 4.3 Single Functi ons, Gantry with 6x Revolver Head (for 80F 5) 05/99 Is sue from Software Version SR.405.xx 4 - 34 4.3.4 V acuum T est, 6x Revolver Head If all n ozzl…

100%1 / 763
SIPLACE 80S-20/F4/F5 User Manual 4 Single Functions
05/99 Issue from Software Version SR.405.xx 4.3 Single Functions, Gantry with 6x Revolver Head (for 80F5)
4 - 33
4.3.3.4 Head Reference Run
When this function is activated, the z and d axes will carry out a reference run.
Within the working area click on the
Head reference run
button. The z and d axes will carry out a refer-
ence run.
4.3.3.5 Turn D Axis
When this function is activated, you can check the d axis. For the check the d axis is rotated.
Within the working area click on the
Turn d axis
button. The d axis will rotate.
4.3.3.6 Z Axis - Unclamp
When this function is activated, clamping of the z axis will be released.
Within the
Z axis
working area click on the
Unclamp
button. The clamping of the z axis is released and a
message window appears.
To activate clamping click on the
OK
button. The message window will be closed and clamping of the z
axis is active.
4.3.3.7 Vacuum - On
When this function is activated, the vacuum is switched on.
Within the
Vacuum
working area click on the
On
button. The vacuum will be switched on.
4.3.3.8 Vacuum - Off
When this function is activated, the vacuum is switched off.
Within the
Vacuum
working area click on the
Off
button. The vacuum will be switched off.
4.3.3.9 Forced air - On
Activate this function to switch on the forced air to the nozzle. If it is active, the vacuum will be switched off at
the same time.
Click on the On button in the Forced air work area. The forced air will be switched on.
4.3.3.10 Forced air - Off
Activate this function to switch off the forced air to the nozzle.
Click on the Off button in the Forced air work area. The forced air will be switched off.
4 Single Functions SIPLACE 80S-20/F4/F5 User Manual
4.3 Single Functions, Gantry with 6x Revolver Head (for 80F5) 05/99 Issue from Software Version SR.405.xx
4 - 34
4.3.4 Vacuum Test, 6x Revolver Head
If all nozzles are at the star, when this function is activated the nozzles will be checked regarding their vacuum
values in the pick-up position.
In the
Gantry functions
menu click on the symbol button for
Vacuum test revolver head.
Fig. 4.3.6 Vacuum test 6x revolver head
Click on the
Measure
button. A head reference run will be carried out and the vacuum values at the pick-
up position measured for all nozzles. The measured values for the open and closed pick-up positions are
displayed.
F
SIPLACE 80S-20/F4/F5 User Manual 4 Single Functions
05/99 Issue from Software Version SR.405.xx 4.3 Single Functions, Gantry with 6x Revolver Head (for 80F5)
4 - 35
4.3.5 Nozzle Offset, 6x Revolver Head
This function is used for determining the nozzle height of all segments. If all segments are in the star the value
found here will refer to Segment 1.
In the In the
Gantry functions
menu click on the symbol button for
Nozzle offset
revolver head
.
Fig. 4.3.7 Nozzle offset 6x revolver head
Click on the
Measure
button.
Press the
Start
button when you are asked to do so on the screen. The active gantry will move to a defined
position above the board conveyor and there carry out measurement of the z height with all segments.
Once measurement is finished the gantry will return to its starting position. The measured nozzle heights
will now be displayed.
F