80S-2080F480F5.pdf - 第24页
0 Introduction SIPLACE 80S-20/F4 /F5 User Manual 0.2 Technical Data 05/99 Issue from Software Version SR.405.xx 0 - 20 0.2.3.8 Permissible Environmental Inf luences 0.2.3.9 Machine control 0.2.3. 10 Com pressed Ai r Spec…

SIPLACE 80S-20/F4/F5 User Manual 0 Introduction
05/99 Issue from Software Version SR.405.xx 0.2 Technical Data
0 - 19
0.2.3.5 Boards, Components, Tapes
0.2.3.6 Connection and Installation Data
0.2.3.7 Machine Dimensions
Boards, components, tapes
Boards (PCB) transport system In-line transport with width adjustment
PCB format
50 mm x 50 mm to 460 mm x 460 mm with PCB buffer
50 mm x 50 mm to 508 mm x 460 mm without PCB buffer
(on request)
Component-free guide edge
of the board
3 mm
Min. PCB thickness 0.5 mm
Max. PCB thickness 4.5 mm
Max. PCB warpage
Upwards: 4.5 mm less PCB thickness
Downwards: 0.5 mm plus the PCB thickness
PCB change time 2.5 sec.
Max. number of 8 mm tapes 80
Tape reel diameter Max. 15“ in the reel container
Connection and installation data
System voltage 230/400 V ± 10 % (50/60 Hz)
System voltage (option for USA) 110/208 V ± 10 % (50/60 Hz)
Total connected load 5 kVA
Total power consumption 5 kW
Fuse protection 3 x 16 A
Compressed air supply Min. 5.5 bar / max. 10 bar
Entire compressed air consumption 250 NL/min.
Machine footprint
Permissible surface load > 1000 kg/m
2
Machine dimensions
Weight base module 1500 kg
Weight fully-equipped Approx. 2000 kg
Length 1587 mm
Width 2425 mm
Height with warning light 1836 mm

0 Introduction SIPLACE 80S-20/F4/F5 User Manual
0.2 Technical Data 05/99 Issue from Software Version SR.405.xx
0 - 20
0.2.3.8 Permissible Environmental Influences
0.2.3.9 Machine control
0.2.3.10 Compressed Air Specification
0.2.3.11 Noise Emission Values
Permissible environmental influences
Room temperature
Between 15
o
C and 35
o
C
Air humidity
30 to 75 %
(on average not higher than 45%, so that under no circum-
stances will there be condensation in or on the machine)
Machine control
Computer machine controller
PC 486
RMOS operating system
Computer station control
Pentium PC
MS-Windows NT 4.0 operating system
Machine control Siemens S5 input/output control
Axis controller Siemens axis controller boards (digital)
Compressed air specification
Max. particle size by density, based on ISO/DIS 8573-1 (Class 1)
Particle size 0.1 µm
Particle density
0.1 mg/m
3
Max. oil content (Class 1)
Particle density 0.01 mg/m
3
Pressure dewpoint (Class 4)
Dewpoint +3
o
Noise emission values specified in accordance with DIN 45 649-1
Emission value at a workstation (L
pAc
) 71 dB (A)
DIN EN ISO 11204 (i)
Sound power level (L
WAc
) 85 dB (A)
E-DIN EN ISO 3744 (i)
001-0307

SIPLACE 80S-20/F4/F5 User Manual 0 Introduction
05/99 Issue from Software Version SR.405.xx 0.3 Installation of the SIPLACE 80 Placement Machine
0 - 21
0.3 Installation of the SIPLACE 80 Placement Machine
0.3.1 SIPLACE 80 Overview
Fig. 0.3.1 SIPLACE 80S-20 overview
- Key to Fig. 0.3.1
1 Length 2 Width
3 Input conveyor 4 Output conveyor
5 Height incl. warning light
(A) = Lifting points for the fork lift
CAUTION
When installing, comply with the Technical Data.