80S-2080F480F5.pdf - 第64页

1 Operational Safety SIPLACE 80S-20/F4/F5 User Manual 1.2 Safety equipment 05/99 Issue from Software Version SR.405.xx 1 - 26 1.2.3 Emergency stop button , protective cover switch and key switch Fig. 1.2.4 Location of th…

100%1 / 763
SIPLACE 80S-20/F4/F5 User Manual 1 Operational Safety
05/99 Issue from Software Version SR.405.xx 1.2 Safety equipment
1 - 25
1.2.2 Guard on the input / output conveyor
DANGER
The guard must always be set to the height of the PCB to be processed. Ensure that the gap between the guard
and the safety bar is as small as possible.
Guards are fitted on the input and output belts of the PCB conveyor.
The height of the guard must be set using the slots so that the processed PCB can travel through.
Fig. 1.2.3 Guard on SIPLACE 80S20/F
4
F
5
- Key to Fig. 1.2.3
1 Safety bar (fixed) 2 Guard (adjustable)
3 Slots for adjusting the height 4 Cover
1 Operational Safety SIPLACE 80S-20/F4/F5 User Manual
1.2 Safety equipment 05/99 Issue from Software Version SR.405.xx
1 - 26
1.2.3 Emergency stop button, protective cover switch and key switch
Fig. 1.2.4 Location of the buttons and protective contactor combination K1, K2
- Key to Fig. 1.2.4
1 Stop button
2 Start button
3 Emergency stop push-button
4 Emergency stop push-button
5 Start button
6 Stop button
7 Component counter
8 Key switch open: position 0 for normal mode
closed: position I for service purposes
9 Protective cover switch (output conveyor, 00303617-xx)
10 Protective cover switch (right, 00321417-xx)
11 Protective cover switch (input conveyor, 00303614-xx)
12 Protective cover switch (left, 00321416-xx)
13 Main switch
14 Protective contactor combination K1
15 Protective contactor combination K2
16 Compressed air unit
SIPLACE 80S-20/F4/F5 User Manual 1 Operational Safety
05/99 Issue from Software Version SR.405.xx 1.2 Safety equipment
1 - 27
1.2.3.1 Functional description
l Emergency stop mushroom-head push-button
When the emergency stop mushroom-head push-button is pressed (item 3 or item 4. in Fig. 1.2.4), the motor
voltage to the gantry axes is switched off. The gantry axes are no longer powered, and thus are not danger-
ous.
PLEASE NOTE
Placement is interrupted and can then either be continued or cancelled once the system is working correctly
once more.
l Protective cover switch
If one of the protective covers is opened (see item 9, 10, 11 or 12 in Fig. 1.2.4), the gantry axes will stop
immediately. They are no longer powered, and thus are not dangerous.
l Key switch
If the key switch (item 8 in Fig. 1.2.4) is closed (position
I
), the star can still be paced at low speed while the
protective covers are open. The gantry axes are no longer powered, and thus are not dangerous.
PLEASE NOTE
The key switch remains open for normal mode, i.e. in the 0 position.
WARNING
The protective covers must only be opened, with the key switch closed (position
I
), by appropriately qualified
and trained personnel.
1.2.3.2 Status messages and the action required
The following displays may appear in placement mode. If they appear, carry out the action specified in the
third column.
Status Display on screen Action required
Emergency stop mushroom-
head push-button pressed
Emergency stop pressed ...
Machine stopped. Release button
Release the pressed emergency stop mush-
room-head push-button (item 3 or 4 in Fig.
1.2.4
)
Press the Start button Press the green Start button (item 2 or 5 in
Fig. 1.2.4)
Tab. 1.2 - 1 Screen displays when the emergency stop mushroom-head push-button is pressed or protective cover is opened