11 Station Extensions/Options SIPLACE 80S-20/F4/F5 User Manual 11.7 Dispenser Flux Application Uni t for SIPLACE 80F4/F5 05/99 Issue from Software Version SR.405.xx 11 - 40 Loosen the cen tering n ozzle. Pull th e cylind…

SIPLACE 80S-20/F4/F5 User Manual 11 Station Extensions/Options
05/99 Issue from Software Version SR.405.xx 11.7 Dispenser Flux Application Unit for SIPLACE 80F4/F5
11 - 39
11.7.5 Replacing the Entire Dispensing Needle with Centering Nozzle
If the centering nozzle is defective, it can be replaced on its own. The dispensing needle is a complete assem-
bly.
It may be necessary to replace the entire dispensing needle if it or the hose is clogged by the formation of
crystals in the flux and thus has to be replaced. In this case, the entire assembly is replaced.
Fig. 11.7.4 Replacing dosing hose (Tube blunt 29”)
- Key to Fig. 11.7.4
1 Tip of dosing needle 2 Centering nozzle
3 Clamping pieces 4 Cylinder cover
5 Dosing needle, complete 6 Valve
7 Cylinder
CAUTION
When you unscrew the centering nozzle, make sure that you do not lose the two clamping pieces which clamp
the dispensing needle in the cylinder.

11 Station Extensions/Options SIPLACE 80S-20/F4/F5 User Manual
11.7 Dispenser Flux Application Unit for SIPLACE 80F4/F5 05/99 Issue from Software Version SR.405.xx
11 - 40
Loosen the centering nozzle.
Pull the cylinder cover and the dispensing needle away from the cylinder and pull out the entire dispensing
needle from the cylinder.
Disconnect the end of the hose of the dispensing needle from the valve of the metering pump.
Thread the new dispensing needle through the cylinder cover and through the cylinder and into the center-
ing nozzle. The tip of the dispensing needle must protrude approximately 3 mm from the centering nozzle.
Tighten the centering nozzle once more.
Push the cylinder cover onto the cylinder.
Check the distance between the dispensing needle and the PCB. Push the piston down as you do so. The
distance must be approximately 1 mm.
If this distance is not correct, it must be reset.
11.7.5.1 Setting the Distance Between the Dispensing Needle and the PCB
Fig. 11.7.5 11.7.5 Setting the distance between the dispensing needle and the PCB
- Key to Fig. 11.7.5
1 Rear cover with 4 fixing screws 2 2 fixing screws for the flux application unit
3 Lifting piston 4 Set the distance to 1 mm from the PCB
5 Push the flux application unit against the stop

SIPLACE 80S-20/F4/F5 User Manual 11 Station Extensions/Options
05/99 Issue from Software Version SR.405.xx 11.7 Dispenser Flux Application Unit for SIPLACE 80F4/F5
11 - 41
Loosen the 4 fixing screws for the rear cover of the flux application unit and then remove the cover.
Loosen the two fixing screw in the slots.
Push the piston down and adjust the flux application unit so that the distance between the tip of the dis-
pensing needle and the PCB is 1 mm.
Push the flux application unit against the lateral stop and tighten the fixing screws.
Fit the rear cover.