80S-2080F480F5.pdf - 第296页

5 Vision Functions SIP LACE 80S-20/F4/F5 Us er Manual 5.5 Teach Fiducial 05/99 Issue from Software Version SR.405.xx 5 - 64 Line en gineer Setting t he contrast se nsitivity t o suppress de fective struct ures and i nten…

100%1 / 763
SIPLACE 80S-20/F4/F5 User Manual 5 Vision Functions
05/99 Issue from Software Version SR.405.xx 5.5 Teach Fiducial
Line engineer 5 - 63
Setting the contrast sensitivity to intensify low-contrast fiducials
Select the following settings for low-contrast fiducials in order to intensify the contrast:
Fig. 5.5.21 Setting the contrast sensitivity to intensify low-contrast fiducials
5 Vision Functions SIPLACE 80S-20/F4/F5 User Manual
5.5 Teach Fiducial 05/99 Issue from Software Version SR.405.xx
5 - 64 Line engineer
Setting the contrast sensitivity to suppress defective structures and intensify the contrast at
the same time
Select the following settings to suppress defective structures and at the same time to intensify the contrast
for low-contrast fiducials:
Fig. 5.5.22 Setting the contrast sensitivity to suppress defective structures and
to intensify the contrast at the same time
SIPLACE 80S-20/F4/F5 User Manual 5 Vision Functions
05/99 Issue from Software Version SR.405.xx 5.5 Teach Fiducial
Line engineer 5 - 65
5.5.6
Test Fiducial
Menu
In the
Test fiducial
menu the following options are available:
Centering the fiducial (Center)
Testing the fiducial (Test)
Positioning the teaching gantry (x/y movement) (move X/Y axes)
Transporting the board onto the output conveyor (PCB to output conveyor)
Transporting the board onto the center conveyor (PCB to center conveyor)
Fig. 5.5.23
Test fiducial
menu, options
NOTE
Buttons are active when the text on the button is black (rather than gray). This means that you can launch the
associated function by clicking on the button with the mouse.
The Center and Test options will only be available if you have already loaded a fiducial and a model already
exists for this fiducial.
If you have selected a fiducial the fiducial number and the fiducial name will appear in the display field.