Portal-Operation-Manual-REV-I.pdf - 第27页

PVA Portal Manual Revision I / Janua ry 2022 Page 27 of 106 6.6.2 Manual Mode Vision Window The Vision Window in Manual mod e is used to set insp ection attri butes, create new fiducials from a t emplate, an d edit and t…

100%1 / 106
PVA Portal Manual
Revision I / January 2022
6.6 Vision
For more information on vision and fiducials, refer to the Vision manual.
6.6.1 Vision Window
Shown below is the standard Vision Window. To access the Vision Window, select the
Vision tab from the System tab section of the screen.
Figure 15: Vision Window
Select the “Zoom button to zoom in or increase the size of the image on the
screen. This option is available for both static and live images.
Select the “Panbutton to move across the zoomed image.
Select the “Center” button to resize the image to its original size and align it with
the center of the screen.
Select the “+” (Crosshair) button to toggle the crosshair overlay on and off. This
option is available for both static and live images.
Select the “Float button to open up a floating vision window that stays on top of
the Portal window.
PVA Portal Manual
Revision I / January 2022
6.6.2 Manual Mode Vision Window
The Vision Window in Manual mode is used to set inspection attributes, create new
fiducials from a template, and edit and test inspections.
Figure 16: Vision Tab
1. Select theNew” button to create a new inspection from a list of templates.
2. Select theEdit” button to take the current image and open NI Vision Builder to edit
the steps of the current inspection.
3. Select the New Pattern drop down menu to create a new pattern.
4. Select the “Test” button to take the current image and run the current inspection.
5. Select the “Snap” button to save the current live image.
6. Select theLive button to toggle the camera live mode on and off.
7. Select the Preview Modecheckbox to toggle the preview mode on and off.
Figure 17: Preview Mode Toggled On
1
2
3
4
6
6
8
9
5
7
10
PVA Portal Manual
Revision I / January 2022
8. Select the “Camera tab to set the camera attributes related to the current
inspection. In this tab, the shutter speed, brightness, and gain can also be adjusted.
Figure 18: Camera Tab Options
Note: The selected program is updated as soon as image adjustments are changed for
shutter speed, brightness, and gain.
9. Select the “Lights tab to toggle the selected light on and off. This is a manual only
function that does not change on the automated inspection. Within the Lights drop
down menu, the FID Light color can be changed to blue, red, green, purple, or white.
Figure 19: Lights Tab