MD600 Series Compact AC Drive Hardware Guide-EN-B06.PDF - 第103页
Option ‑ 102 ‑ 12 Option 12.1 List of Options Optional peripherals include braking units and external operating panels, as listed in the following table. For use of each option, see its user guide. If any optional part i…

Technical Data
‑101‑
11.5 Product dimensions
Figure 11‑2 Outline dimensions and mounting dimensions of T1 to T2 models
Table 11–4 Outline dimensions and mounting dimensions of T1 to T2 models
St-
r-
u-
ct-
u-
re
Mou-
nting
hole
mm
(in.)
Outline dimension mm (in.)
Mounting
Hole Di-
ameter
(mm/
inch)
Weight
(kg/lb)
W1 W2 H1 H2 H H3 H4 H5 H6 W D
T1 54.5
(2.15)
30
(1.18)
159.5
(6.28)
5
(0.2)
170
(6.6-
9)
160
(6.3-
0)
158
(6.22)
17.5
(0.69)
17
(0.67)
60
(2.36)
120
(4.72)
Φ5 (0.20) 0.8 (1.76)
T2 62.5
(2.46)
34
(1.34)
159.5
(6.28)
5
(0.2)
170
(6.6-
9)
160
(6.3-
0)
158
(6.22)
22
(0.87)
24
(0.95)
68
(2.68)
140
(5.51)
Φ5 (0.20) 1 (2.20)

Option
‑102‑
12 Option
12.1 List of Options
Optional peripherals include braking units and external operating panels, as listed in the
following table. For use of each option, see its user guide. If any optional part is required,
specify it in your order.
Table 12–1 List of Options
Catego
ry
Name
Option model Ordering no. Applicable Model
Function
External
operat
ing
panel
Hand-held LCD
operating panel
SOP-20-810 01040028 All models The external LCD operation panel
supports Chinese and English
display, parameter copying, and
connection to the commissioning
software.
Smart operating
panel
MD-BP-M 01040264 All models The external LED operating panel
supports digital and English
display, parameter setting, and
status monitoring.
Cable Main circuit
cable
The recommended cable lug manufacturer is
Zhejiang Kise. For details of recommended lugs, see
"12.9.3 Terminal
"
on page 128
.
It is recommended to use
symmetrical shielded cables as
input and output main circuit
cables. Compared with four-core
cables, symmetrical shielded
cables can reduce electromagnetic
radiation in the whole drive
system. It is recommended that
power cables also use symmetrical
shielded cables.
Control circuit
cable
All control circuit cables must be shielded cables. Use separate shielded cables for
different analog signals. It is recommended to use shielded twisted pair (STP) cables as
digital signal cables.
Extension cable MDCAB 01013008 All models The standard 8-conductor network
cable can be used to connect to the
SOP-20-810 through the network
port or connect to the
commissioning software installed
on the computer through the relay
mode of the SOP-20-810.

Option
‑103‑
Catego
ry
Name
Option model Ordering no. Applicable Model
Function
Accesso
ries
Guide rail
installation
accessory
MD600-DGJ1 01040265 Applicable only to
T1 models (three-
phase 380 V to
480 V: 0.37 kW to
2.2 kW; single-
phase 200 V to
240 V: 0.37 kW to
1.5 kW)
Guide rail installation accessory
SOP-20-810
mounting base
CP600–BASE1 01040022 All models It is used to install the SOP-20-810
to the cabinet door.
Note
For the list of peripheral electrical devices, see related section.