MD600 Series Compact AC Drive Hardware Guide-EN-B06.PDF - 第112页
Option ‑111‑ Dimensions Dimensions of the AC output reactor: Figure 12‑9 Dimensions of the AC output reactor (5-10 A) Table 12–8 Dimensions of the AC output reactor (5-15 A) (unit: mm) Model A B C G F I J MD-OCL-5-1.4-4T…

Option
‑110‑
12.5 Output Reactors
With an output reactor installed on the output side of the drive, the excessive dV/dt can
be reduced. This can reduce the voltage stress on the motor winding to protect it, lower
the motor temperature, and prolong the service life of the motor. Whether to install an
output reactor on the output side of the AC drive is dependent on the actual situation. The
cable connecting the AC drive and motor cannot be too long. Otherwise, large distributed
capacitance and high harmonics current will be caused. When the application
environment has high requirements on grid harmonics suppression, you can choose an
optional reactor as required.
Inovance AC output reactor
Models and dimensions of the recommended Inovance AC output reactors are as follows.
Figure 12‑8 AC output reactor model
①
Internal code
MD-OCL: Inovance AC output reactor
④
Rated voltage
4T: 380V
②
Rated current
50: 50 A
⑤
Voltage drop percentage
1%: 1%
③
Inductance
0.14: 0.14 mH
-
Table 12–6 Recommended models of the AC output reactor (single-phase 200–240 V)
Structure AC Drive Model Rated current
(A)
Rated power
(kW)
Reactor model Inductance
(mH)
T1
MD600S/A-2S2R8(B)
2.8 0.37 MD-OCL-5-1.4-4T-1% 1.4
MD600S/A-2S4R6(B)
4.6 0.75 MD-OCL-7-1.0-4T-1% 1.0
MD600S/A-2S7R5(B)
7.5 1.5 MD-OCL-10-0.7-4T-1% 0.7
T2
MD600S/A-2S010(B)
10 2.2 MD-OCL-15-0.47-4T-1% 0.47
Table 12–7 Recommended models of the AC output reactor (three-phase 380–480 V)
Structure AC Drive Model Rated current
(A)
Rated power
(kW)
Reactor model Inductance
(mH)
T1
MD600S/A-4T1R6(B)
1.6 0.37 MD-OCL-5-1.4-4T-1% 1.4
MD600S/A-4T2R3(B)
2.3 0.75 MD-OCL-5-1.4-4T-1% 1.4
MD600S/A-4T4R8(B)
4.8 1.5 MD-OCL-7-1.0-4T-1% 1.0
MD600S/A-4T5R5(B)
5.5 2.2 MD-OCL-10-0.7-4T-1% 0.7
T2
MD600S/A-4T9R5(B)
9.5 4 MD‑OCL‑15‑0 .47‑4T‑1% 0.47
MD600S/A‑4T013(B)
13 5.5 MD‑OCL‑15‑0 .47‑4T‑1% 0.47

Option
‑111‑
Dimensions
Dimensions of the AC output reactor:
Figure 12‑9 Dimensions of the AC output reactor (5-10 A)
Table 12–8 Dimensions of the AC output reactor (5-15 A) (unit: mm)
Model A B C G F I J
MD-OCL-5-1.4-4T-1% 105 ± 1 130 110 84 ± 2 65 ± 2 91 ± 1 Φ6x11
MD-OCL-7-1.0-4T-1% 105 ± 1 130 110 84 ± 2 65 ± 2 91 ± 1 Φ6x11
MD-OCL-10-0.7-4T-1% 105 ± 1 130 110 84 ± 2 65 ± 2 91 ± 1 Φ6x11