MD600 Series Compact AC Drive Hardware Guide-EN-B06.PDF - 第93页

Technical Data ‑ 92 ‑ Model Model Structure Power (kW) Rated input current (A) Rated output current (A) Product code Function Cooling method Built- in Brak ing Unit CAN MD600A‑4T1R6 T1 0.37 1.9 1.6 0101C55 2 CAN communi …

100%1 / 135
Technical Data
‑91‑
Model Model Structure
Power
(kW)
Rated
input
current
(A)
Rated
output
current
(A)
Product
code
Function
Cooling
method
Built-
in
Brak
ing
Unit
CAN MD600A‑2S2R8 T1 0.37 6.2 2.8 0101C55
1
CAN
communi
cation
Natural
ly-
ventilat
ed
None
MD600A‑2S2R8
B
T1 0101C
R69
CAN
communi
cation
Natural
ly-
ventilat
ed
Yes
MD600A‑2S4R6 T1 0.75 10.2 4.6 0101C55
5
CAN
communi
cation
Air
cooling
None
MD600A‑2S4R6
B
T1 0101C
R70
CAN
communi
cation
Air
cooling
Yes
MD600A‑2S7R5 T1 1.5 16.6 7.5 0101C
R62
CAN
communi
cation
Air
cooling
None
MD600A‑2S7R5
B
T1 0101C55
6
CAN
communi
cation
Air
cooling
Yes
MD600A‑2S010 T2 2.2 22.2 10 0101C
R88
CAN
communi
cation
Air
cooling
None
MD600A‑2S010
B
T2 0101C55
9
CAN
communi
cation
Air
cooling
Yes
Three-phase 380 V to 480 V
Technical Data
‑92‑
Model Model Structure
Power
(kW)
Rated
input
current
(A)
Rated
output
current
(A)
Product
code
Function
Cooling
method
Built-
in
Brak
ing
Unit
CAN MD600A‑4T1R6 T1 0.37 1.9 1.6 0101C55
2
CAN
communi
cation
Natural
ly-
ventilat
ed
None
MD600A‑4T1R6
B
T1 0101C
R66
CAN
communi
cation
Natural
ly-
ventilat
ed
Yes
MD600A‑4T2R3 T1 0.75 2.8 2.3 0101C55
4
CAN
communi
cation
Natural
ly-
ventilat
ed
None
MD600A‑4T2R3
B
T1 0101C
R58
CAN
communi
cation
Natural
ly-
ventilat
ed
Yes
MD600A‑4T4R8 T1 1.5 5.9 4.8 0101C55
7
CAN
communi
cation
Air
cooling
None
MD600A‑4T4R8
B
T1 0101C
R60
CAN
communi
cation
Air
cooling
Yes
MD600A‑4T5R5 T1 2.2 6.7 5.5 0101C
R61
CAN
communi
cation
Air
cooling
None
MD600A‑4T5R5
B
T1 0101C55
8
CAN
communi
cation
Air
cooling
Yes
MD600A‑4T9R5 T2 4 11.6 9.5 0101C
R92
CAN
communi
cation
Air
cooling
None
MD600A‑4T9R5
B
T2 0101C56
0
CAN
communi
cation
Air
cooling
Yes
MD600A‑4T013 T2 5.5 15.8 13 0101C
R64
CAN
communi
cation
Air
cooling
None
MD600A‑4T013
B
T2 0101C55
3
CAN
communi
cation
Air
cooling
Yes
Technical Data
‑93‑
11.2 Selection Instance
Selection flow
The following figure shows the AC drive selection flow.
Figure 11‑1 Selection flow
Example
The following part takes MD600S-4T1R6 as an example.
1. The voltage of MD600S-4T1R6 is three-phase 380 V to 480 V.
2. The current of the MD600S-4T1R6 is 1.6 A.
3. The MD600S-4T1R6 supports RS485 communication.
4. The peripheral devices of the MD600S-4T1R6 include the AC input reactor MD-ACL-10-
5-4T, output reactor MD-OCL-5-1.44, and EMC filter FN 3287-10-44-C28-R65.