Technical Data ‑89‑ 11 Technical Data 11.1 Model Selection List See the following table for key specifications. Table 11–1 Model Selection List Model Model Structure Power (kW) Rated input current (A) Rated output curren…

100%1 / 135
Maintenance and Repair
‑88‑
10.2.2Replacing the Fan
Removing the fan
The MD600 fan can be removed without any tool.
Press and hold the four snap-fit joints around the fan to pull the fan out, as shown by ①.
Figure 10‑1 Fan removal
Installing the fan
Align the fan terminal with the slot as shown in ① and push the fan toward the drive until
the snap-fit joints are in the places.
Figure 10‑2 Fan installation
Note
For RS485 and CAN models, single-phase 0.75 kW, 1.5 kW, and 2.2 kW AC drives, as well
as three-phase 1.5 kW, 2.2 kW, 4 kW, and 5.5 kW AC drives provide one fan.
Technical Data
‑89‑
11 Technical Data
11.1 Model Selection List
See the following table for key specifications.
Table 11–1 Model Selection List
Model Model Structure
Power
(kW)
Rated
input
current
(A)
Rated
output
current
(A)
Product
code
Function
Cooling
method
Built-
in
Brak
ing
Unit
Single-phase 200 V to 240 V
RS-485
MD600S‑2S2R8 T1 0.37 6.2 2.8 0101C42
7
RS485
Communi
cation
Natural
ly-
ventilat
ed
None
MD600S‑2S2R8B T1 0101C
R67
RS485
Communi
cation
Natural
ly-
ventilat
ed
Yes
MD600S‑2S4R6 T1 0.75 10.2 4.6 0101C52
3
RS485
Communi
cation
Air
cooling
None
MD600S‑2S4R6B T1 0101C
R68
RS485
Communi
cation
Air
cooling
Yes
MD600S‑2S7R5 T1 1.5 16.6 7.5 0101C
R63
RS485
Communi
cation
Air
cooling
None
MD600S‑2S7R5B T1 0101C52
4
RS485
Communi
cation
Air
cooling
Yes
MD600S‑2S010 T2 2.2 22.2 10 0101C
R87
RS485
Communi
cation
Air
cooling
None
MD600S‑2S010B T2 0101C52
1
RS485
Communi
cation
Air
cooling
Yes
Three-phase 380 V to 480 V
Technical Data
‑90‑
Model Model Structure
Power
(kW)
Rated
input
current
(A)
Rated
output
current
(A)
Product
code
Function
Cooling
method
Built-
in
Brak
ing
Unit
RS-485 MD600S‑4T1R6 T1 0.37 1.9 1.6 0101C43
1
RS485
Communi
cation
Natural
ly-
ventilat
ed
None
MD600S‑4T1R6B T1 0101C
R53
RS485
Communi
cation
Natural
ly-
ventilat
ed
Yes
MD600S‑4T2R3 T1 0.75 2.8 2.3 0101C43
2
RS485
Communi
cation
Natural
ly-
ventilat
ed
None
MD600S‑4T2R3B T1 0101C
R55
RS485
Communi
cation
Natural
ly-
ventilat
ed
Yes
MD600S‑4T4R8 T1 1.5 5.9 4.8 0101C52
2
RS485
Communi
cation
Air
cooling
None
MD600S‑4T4R8B T1 0101C
R56
RS485
Communi
cation
Air
cooling
Yes
MD600S‑4T5R5 T1 2.2 6.7 5.5 0101C
R57
RS485
Communi
cation
Air
cooling
None
MD600S‑4T5R5B T1 0101C42
8
RS485
Communi
cation
Air
cooling
Yes
MD600S‑4T9R5 T2 4 11.6 9.5 0101C
R91
RS485
Communi
cation
Air
cooling
None
MD600S‑4T9R5B T2 0101C52
0
RS485
Communi
cation
Air
cooling
Yes
MD600S‑4T013 T2 5.5 15.8 13 0101C
R52
RS485
Communi
cation
Air
cooling
None
MD600S‑4T013B T2 0101C42
9
RS485
Communi
cation
Air
cooling
Yes
Single-phase 200 V to 240 V