MD600 Series Compact AC Drive Hardware Guide-EN-B06.PDF - 第94页
Technical Data ‑93‑ 11.2 Selection Instance Selection flow The following figure shows the AC drive selection flow. Figure 11‑1 Selection flow Example The following part takes MD600S-4T1R6 as an example. 1. The voltage of…

Technical Data
‑92‑
Model Model Structure
Power
(kW)
Rated
input
current
(A)
Rated
output
current
(A)
Product
code
Function
Cooling
method
Built-
in
Brak
ing
Unit
CAN MD600A‑4T1R6 T1 0.37 1.9 1.6 0101C55
2
CAN
communi
cation
Natural
ly-
ventilat
ed
None
MD600A‑4T1R6
B
T1 0101C
R66
CAN
communi
cation
Natural
ly-
ventilat
ed
Yes
MD600A‑4T2R3 T1 0.75 2.8 2.3 0101C55
4
CAN
communi
cation
Natural
ly-
ventilat
ed
None
MD600A‑4T2R3
B
T1 0101C
R58
CAN
communi
cation
Natural
ly-
ventilat
ed
Yes
MD600A‑4T4R8 T1 1.5 5.9 4.8 0101C55
7
CAN
communi
cation
Air
cooling
None
MD600A‑4T4R8
B
T1 0101C
R60
CAN
communi
cation
Air
cooling
Yes
MD600A‑4T5R5 T1 2.2 6.7 5.5 0101C
R61
CAN
communi
cation
Air
cooling
None
MD600A‑4T5R5
B
T1 0101C55
8
CAN
communi
cation
Air
cooling
Yes
MD600A‑4T9R5 T2 4 11.6 9.5 0101C
R92
CAN
communi
cation
Air
cooling
None
MD600A‑4T9R5
B
T2 0101C56
0
CAN
communi
cation
Air
cooling
Yes
MD600A‑4T013 T2 5.5 15.8 13 0101C
R64
CAN
communi
cation
Air
cooling
None
MD600A‑4T013
B
T2 0101C55
3
CAN
communi
cation
Air
cooling
Yes

Technical Data
‑93‑
11.2 Selection Instance
Selection flow
The following figure shows the AC drive selection flow.
Figure 11‑1 Selection flow
Example
The following part takes MD600S-4T1R6 as an example.
1. The voltage of MD600S-4T1R6 is three-phase 380 V to 480 V.
2. The current of the MD600S-4T1R6 is 1.6 A.
3. The MD600S-4T1R6 supports RS485 communication.
4. The peripheral devices of the MD600S-4T1R6 include the AC input reactor MD-ACL-10-
5-4T, output reactor MD-OCL-5-1.44, and EMC filter FN 3287-10-44-C28-R65.

Technical Data
‑94‑
11.3 Electrical Specifications
Note
In the following tables, the rated power of the drive is measured under the following
conditions.
● For single-phase 200 V to 240 V models, the rated power is measured at the
input voltage of 230 VAC.
● For three-phase 380 V to 480 V models, the rated power of the drive is measured
at an input voltage of 400 VAC.
Single-phase 200 V to 240 V
Table 11–2 Electrical specifications for T1 to T2 models (single-phase 200 V to 240 V)
Item
Specification
Model: MD600S/A-2Sxxxxx(B) 2R8 4R6 7R5B
010 B
Structure T1 T2
Input Rated input current (A) 6.2 10.2 16.6 22.2
Rated voltage/Rated
frequency
Single-phase 200 VAC to 240 VAC, 50/60 Hz
Allowable voltage
fluctuation range
-15% to +10%, or 170 VAC to 264 VAC
Allowable frequency
fluctuation range
±5%; actual allowable range: 47.5 Hz to 63 Hz
Power capacity (kVA) 1.5 2.4 4 5.3
Output Power (kW) 0.37 0.75 1.5 2.2
Rated output current (A) 2.8 4.6 7.5 10
Output voltage Three-phase 0 V to input voltage
Maximum output frequency 599 Hz
Carrier frequency 0.5 kHz to 16.0 kHz (automatically adjusted according to the load)
Overload capacity overload: 60s at 150% of the rated current continuously
Thermal
design
Thermal Loss (W) 22 36 55 77
Exhaust flow (CFM) - 12 12 19