Technical Data
‑96‑
11.4 General Specifications
Item Technical specifications
Motor
control
perform
ance
Applicable motor type Asynchronous induction motor (IM) and permanent magnet synchronous
motor (PMSM)
Control mode Sensorless vector control (SVC), and voltage/frequency (V/f) control
Asynchronous
motor (V/f)
Functions
available
Energy-saving control, overvoltage suppression, overcurrent
suppression, undervoltage suppression (voltage dip suppression),
oscillation suppression, torque boost, slip compensation, V/f curve
selection, decoupled V/f, DC braking, random PWM, fast deceleration
upon over-excitation, and droop control
Asynchronous
motor (SVC)
Functions
available
Energy-saving control, inertia auto-tuning, acceleration feedforward,
adaptive speed loop parameters, droop control, free programming and
self-adaption of speed loop parameters, load observer, overvoltage
suppression, undervoltage suppression (voltage dip suppression), over-
excitation fast deceleration, automatic voltage adjustment, flying start,
and DC braking
Speed
regulation
range
1:500
Starting torque 200%
Torque step
response
Within 2 ms
Torque control
accuracy
±3% at frequencies above 5 Hz
Speed stability
accuracy
Within 10% of the rated slip value
Field
weakening
ratio
6 x field weakening
Permanent
magnet
synchronous
motor
Functions
available
Speed tracking, electronic star connection, fast deceleration upon over-
excitation, MTPA maximum torque-to-current ratio control, inertia auto-
tuning and acceleration feedforward, droop control, adaptive speed loop
parameter programming, overvoltage suppression, undervoltage
suppression, DC braking, I/F control in SVC
Speed
regulation
range
1:200
Starting torque 200%
Torque step
response
Within 2 ms
Speed stability
accuracy
0.05% (without motor defects)
Torque control
accuracy
±3% at frequencies above 5 Hz
Technical Data
‑97‑
Item Technical specifications
Basic
func
tions
Resolution of input frequency Digital setting: 0.01 Hz
Analog setting: maximum frequency x 0.025%
Operation Operation
command
Independent dual channel and dual channel, which can be switched
freely
Provides different start/stop sources (terminal, operating panel,
communication, custom, connector).
Provides standard control word.
Frequency
reference
Independent dual channel and dual channel, which can be switched
freely
Provides various sources (communication, operating panel, analog,
connector, and so on).
Supports main frequency, auxiliary frequency, and various operations
(addition, subtraction, multiplication, Max., and Min.).
Supports additional frequency.
Supports multi-level frequency limits.
Auxiliary
frequency
reference
Supports various auxiliary frequency references and allows fine-tuning of
the auxiliary frequencies and frequency synthesis.
Standard
command
word
Normal start/stop (OFF1)
Emergency stop (OFF2)
Quick stop, stop with maximum capability (OFF3)
Operation enable, operation pause
Torque
reference
Multiple torque reference sources: digital reference, analog voltage
reference, analog current reference, pulse reference, multi-reference,
PID, simple PLC, and communication, which can be switched through
multiple ways
Start/Stop
mode
Dual channel, which can be switched freely
Supports six different start/stop modes (single-wire mode, two-wire
mode 1, two-wire mode 2, two-wire mode 3, three-wire mode 1, three-
wire mode 2)
Acceleration/
Deceleration
time
Linear acceleration/deceleration and S-curve acceleration/deceleration
4 sets of acceleration/deceleration time
7-segment S-curve can be independently configured.
Automatic switchover between acceleration/deceleration
Multi-speed Supports up to 16 multi-speed references.
Supports different unit settings (Hz, rpm, rated %, maximum speed %).
Supports free per-unit conversion.
Supports custom limit.
Ramp transition function When speed references are sent through communication cyclically,
automatic interpolation is supported to rectify command discontinuity
caused by communication intervals, ensuring smooth operation.
Output limit Torque limit, power limit, current limit, maximum/minimum torque limit,
and speed limit
Technical Data
‑98‑
Item Technical specifications
MD600S
commis
sioning
and
configu
ration
(human
machine
inter
face)
Control
Interfaces
Analog input One analog input:
AI1: -10 V to +10 V/0 mA to 20 mA
Voltage and current: calibration accuracy 0.3%, response time shorter
than 2 ms
Analog output MD600S: one analog output; AO1: 0 V to 10 V; calibration accuracy: 100
mV; resolution: 12-bit; calibration accuracy: 0.5%
MD600A: no analog output
Digital input. MD600A: four common inputs; one high-speed input; NPN/PNP input
wiring method; DI4 used as high-speed pulse input; 20 kHz frequency
MD600S: four common inputs, NPN/PNP input wiring method
Digital output Relay output: two contacts, 3 A/250 VAC, 3 A/30 VDC, with normally open
and normally closed functions supported:
MD600A: two common digital outputs; frequency: 100 Hz, output voltage
range: 0 V to 24 V; output current range: 0 mA to 50 mA
Display and
operations on
the operating
panel
LED operating
panel
Used to display and change parameters and display drive status (forward
run, reverse run, stop, operating panel/terminal/communication control,
speed/torque control).
Key lock and
function
To prevent inadvertent operations, keys on the operating panel can be
locked partially, and functions with limited availability range can be
assigned to some keys.
Commissioning software tool The commissioning software (iFA Drive/InoDriverShop) supports
uploading and downloading drive parameters and oscilloscope
functions. You can monitor internal status of the drive through the
oscilloscope.
Function logic is presented using data flow diagrams, enabling manual-
free commissioning.
This helps reduce the learning cost and shorten commissioning time.
Parameter protection Supports parameter access write protection to prevent inadvertent
parameter modification.
User password (parameter lock) Supports user-defined passwords to protect parameter accessibility.
Parameter access levels Standard: default level with access to commonly used function
parameters
Extended: Extended with non-frequent function parameters
Expert: Parameters for experts, which can be set with a password