MD600 Series Compact AC Drive Hardware Guide-EN-B06.PDF - 第25页

Product Information ‑ 24 ‑ Table 2–2 Relationship between the product model and structure (CAN version) Struc ture Three-phase 380 V to 480 V Single-phase 200 V to 240 V Power (kW) Product model Power (kW) Product model …

100%1 / 135
Product Information
‑23‑
Description of serial number
①
Internal code
Product material code
④
Month
1: January
2: February
3: March
...
C: December
②
Manufacturer code
4: Suzhou Inovance
⑤
Lot number
00001: First
00002: Second
00003: Third
...
Range: 00001 to 99999
③
Year
R: 2023
S: 2024
Note: I/L/O/Q are skipped.
-
2.3 Product Model List
The following tables list mappings between the product model and structure.
Table 2–1 Relationship between the product model and structure (RS-485 version)
Struc
ture
Three-phase 380 V to 480 V Single-phase 200 V to 240 V
Power (kW)
Product model
Power (kW)
Product model
T1 0.37
MD600S-4T1R6(B)
0.37
MD600S-2S2R8(B)
0.75
MD600S-4T2R3(B)
0.75
MD600S-2S4R6(B)
1.5
MD600S-4T4R8(B)
1.5
MD600S-2S7R5(B)
2.2
MD600S-4T5R5(B)
T2 4
MD600S-4T9R5(B)
2.2
MD600S-2S010(B)
5.5
MD600S‑4T013(B)
Product Information
‑24‑
Table 2–2 Relationship between the product model and structure (CAN version)
Struc
ture
Three-phase 380 V to 480 V Single-phase 200 V to 240 V
Power (kW)
Product model
Power (kW)
Product model
T1 0.37
MD600A-4T1R6(B)
0.37
MD600A-2S2R8(B)
0.75
MD600A-4T2R3(B)
0.75
MD600A-2S4R6(B)
1.5
MD600A-4T4R8(B)
1.5
MD600A-2S7R5(B)
2.2
MD600A-4T5R5(B)
T2 4
MD600A-4T9R5(B)
2.2
MD600A-2S010(B)
5.5
MD600A‑4T013(B)
2.4 Components
Figure 2‑2 Components
No. Name
Remarks
1
LED display on the
operating panel
It displays the axis number, status, unit, and data.
2
Keys on the
operating panel
It is used for operations through the operating
panel.
3
Communication
terminal (CN1/
CN2)
-
4
Control circuit
terminal (CN4)
It integrates the Modbus RTU communication,
analog input, analog output, digital input, digital
output, 24 V power supply output, and 10 V power
supply output signals.
5
Product nameplate It displays the product information.
6
DIP switch for
termination
resistor
DIP switch for the Modbus communication
termination resistor in CN1
DIP switch for the CAN communication termination
resistor in CN1 and CN2
Product Information
‑25‑
No. Name
Remarks
7
Relay terminal
(CN3)
Relay output terminal
8
R (L1)/S/T (L2)/PE
input terminals
It is used to connect three-phase/single-phase AC
input power supplies. R/S/T terminals are used to
connect the three-phase power supply. L1/L2
terminals are used to connect the single-phase
power supply, and PE is the protective earthing
terminal.
9
Braking terminal It is used to connect the braking resistor.
10
U/V/W/PE output
terminals
U/V/W terminals are used to connect the three-
phase motor, and PE is the protective earthing
terminal.
11
Cooling fan It is used for heat dissipation.