00196962-04-BA-SX12-V2-EN.pdf - 第158页
3 Technical data and assemblies User manual SIPLACE SX1/SX2 3.9 X feeder modules for SIPLACE SX1/SX2 From software version SC 706.1 SP1 Version 10/2014 158 3.9.2.1 1 T ape feeder module 72 mm X 3 Fig. 3.9 - 13 T ape feed…

User manual SIPLACE SX1/SX2 3 Technical data and assemblies
From software version SC 706.1 SP1 Version 10/2014 3.9 X feeder modules for SIPLACE SX1/SX2
157
3.9.2.10 Tape feeder module 56 mm X
3
Fig. 3.9 - 12 Tape feeder module 56 mm X
3
3
3
Tape feeder module 56 mm X Item no. 00141276-xx
56 mm X tape feeder module with splice sensor Item no. 00141296-xx
Width 69,8
Feeder module locations filled 6
Conveyor increment From 4 mm to 64 mm in 4 mm increments
Changeover time for the component tape < 45 s
Changeover time for the preset feeder module
on the machine
≤ 8 s

3 Technical data and assemblies User manual SIPLACE SX1/SX2
3.9 X feeder modules for SIPLACE SX1/SX2 From software version SC 706.1 SP1 Version 10/2014
158
3.9.2.11 Tape feeder module 72 mm X
3
Fig. 3.9 - 13 Tape feeder module 72 mm X
3
3
3
72 mm X tape feeder module with splice sensor Item no. 00141297-xx
Width 81,6
Feeder module locations filled 7
Conveyor increment From 4 mm to 80 mm in 4 mm increments
Changeover time for the component tape < 45 s
Changeover time for the preset feeder module
on the machine
≤ 8 s

User manual SIPLACE SX1/SX2 3 Technical data and assemblies
From software version SC 706.1 SP1 Version 10/2014 3.9 X feeder modules for SIPLACE SX1/SX2
159
3.9.2.12 Tape feeder module 88 mm X
3
Fig. 3.9 - 14 Tape feeder module 88 mm X
3
3
88 mm X tape feeder module with splice sensor Item no. 00141298-xx
Width 105.2 mm
Feeder module locations filled 9
Conveyor increment From 4 mm to 96 mm in 4 mm increments
Changeover time for the component tape < 45 s
Changeover time for the preset feeder module
on the machine
≤ 8 s