00196962-04-BA-SX12-V2-EN.pdf - 第353页

User manual SIPLACE SX1/SX2 6 Station extensions From software version SC 706.1 SP1 Version 10/2014 6.19 Capacity on Demand 353 6.19.2 SIPLACE Cap acity On Demand business models The Peak-Deman d models addresses the nee…

100%1 / 370
6 Station extensions User manual SIPLACE SX1/SX2
6.19 Capacity on Demand From software version SC 706.1 SP1 Version 10/2014
352
6.19 Capacity on Demand
6.19.1 General
Capacity on Demand: Convincing answers in all situations. Modern electronic production knows
only one constant factor: change. The SIPLACE SX allows you to adapt your production environ-
ment to different business requirements and to continue operating with high efficiency despite
changing productions scenarios. Start small and enjoy quick and easy growth whenever needed.
6
Fig. 6.19 - 1 Capacity on Demand
Free transfer of placement capacity between the lines
This enables you to take SX changeover gantries from lines with lower utilization or to borrow gan-
tries from SIPLACE. This transfers targeted placement capacity to lines experiencing bottlenecks.
Scaling SMT lines synchronous to ramp-up
Scale your line synchronously to the actual requirement. The SX changeover gantries give your
lines reserve capacity which you can call on without risk, when your specific requirement in-
creases.
Borrow capacity for no-risk and easy coverage of peak requirements
Use SX changeover gantries to borrow the additional placement capacity needed on demand.
This gives you a flexible reserve for peak times, helps minimize costs and avoid excess capacity.
Targeted location quantity and flexibility increases
Invest for your specific needs with a SX+ basic module with locations. You save the costs of heads
and gantries. Just move the existing SX changeover gantries to the new basic module.
Transferring gantries
between the STM lines
Scaling gantries for
ramp-up
Lending out gantries
for enhanced place-
ment performance
Increasing locations
as required
Fully flexible produc-
tion
User manual SIPLACE SX1/SX2 6 Station extensions
From software version SC 706.1 SP1 Version 10/2014 6.19 Capacity on Demand
353
6.19.2 SIPLACE Capacity On Demand business models
The Peak-Demand models addresses the need to cover short-term fluctuations with existing SI-
PLACE SX lines. The other model, Floating-Demand, provides customers with an alternative to
the standard package, thereby improving their financial flexibility, increasing asset productivity and
allowing full exploitation of the benefits offered with a SIPLACE SX solution.
6.19.3 Overview of SIPLACE SX machines
The SIPLACE SX must be prepared for a gantry upgrade. The SIPLACE SX machines are avail-
able in different variants.
6
The head configurations available may be limited, according to the design concerned.
Machine type Gantries Description
SIPLACE SX +
Without gan-
try
The machine is prepared for a gantry upgrade (SX1), i.e.
a trailing cable and two Gantry Control Units (GCU) are
preinstalled for one gantry.
SIPLACE SX +
Prepared
Without gan-
try
The machine is prepared for a gantry upgrade (SX1/2),
i.e. two trailing cables and three Gantry Control Units
(GCU) are preinstalled for two gantries.
SIPLACE SX1
unprepared
One gantry The machine is not prepared for a gantry upgrade (SX1),
i.e. the trailing cable and two Gantry Control Units (GCU)
are preinstalled for one gantry. An upgrade to SIPLACE
SX2 needs to be performed by the SIPLACE Service
team.
SIPLACE SX1
prepared
One gantry The machine is prepared for a gantry upgrade (SX2), i.e.
two trailing cables and three Gantry Control Units (GCU)
are preinstalled for two gantries.
SIPLACE SX2
Two gantries The machine can be torn down to give a SIPLACE SX1
Prepared. The machine is then prepared for a gantry
upgrade to SX2, i.e. two trailing cables and three Gantry
Control Units (GCU) are available.
6 Station extensions User manual SIPLACE SX1/SX2
6.19 Capacity on Demand From software version SC 706.1 SP1 Version 10/2014
354
6.19.4 Head configurations
6
SIPLACE SX +
Gantry Heads
1
C&P20 A
CPP
(Low)
CPP (High)
*a
Without stationary camera
TH
*b
SIPLACE SX + Prepared
Gantry Heads
1
C&P20 A
CPP
(Low)
CPP (High)
a
With stationary camera
CPP (High)
a
Without stationary camera
TH
b
TH
b
2
C&P20 A
CPP
(Low)
CPP (High)
a
Without stationary camera
TH
b
CPP
(High)
TH
b
SIPLACE SX1
Gantry Heads
1
C&P20 A
CPP
(Low)
CPP (High)
a
With stationary camera
CPP (High)
a
Without stationary camera
TH
b
TH
b
with upgrade kit from SIPLACE Service
2
C&P20 A
CPP
(Low)
CPP (High)
a
Without stationary camera
TH
b
CPP
(High)
TH
b
SIPLACE SX1 prepared
Gantry
Heads
1
C&P20 A
CPP
(Low)
CPP (High)
a
With stationary camera
CPP (High)
a
Without stationary camera
TH
b
TH
b
2
C&P20 A
CPP
(Low)
CPP (High)
a
Without stationary camera
TH
b
CPP
(High)
TH
b
SIPLACE SX 2
Gantry Heads
1
C&P20 A
CPP
(Low)
CPP (High)
a
With stationary camera
CPP (High)
a
Without stationary camera
TH
b
TH
b
2
C&P20 A
CPP
(Low)
CPP (High)
a
Without stationary camera
TH
b
CPP
(High)
TH
b
*)a CPP (high), TH and stationary camera require outer table position