User manual SIPLACE SX1/SX2 4 Setting up and commissioning From software version SC 706.1 SP1 Version 10/2014 4.2 Infrastructure at the installation location 193 4.2.3 Main power supply 4 Fig. 4.2 - 2 Position of the pow…

4 Setting up and commissioning User manual SIPLACE SX1/SX2
4.2 Infrastructure at the installation location From software version SC 706.1 SP1 Version 10/2014
192
4.2.2.2 Compressed air connection on the machine
4
Fig. 4.2 - 1 Compressed air unit on the machine
Legend for fig.4.2 - 1
(1) Manometer for supply pressure of gantries 1 and 2
Target pressure: 0.46 ± 0.01 MPa, 4.6 ± 0.1 bar (display range 0 - 0.6 MPa, 0 - 6 bar)
(2) Manometer for the machine component supply pressure
Target pressure: 0.5 ± 0.025 MPa, 5 ± 0.25 bar (display range 0 - 0.6 MPa, 0 - 6 bar)
(3) Manometer for the bulkcase feeder module supply pressure
Target pressure: 0.25 ± 0.05 MPa, 2.5 ± 0.5 bar (display range: 0 - 0.6 MPa, 0 - 6 bar)
(4) Manometer for inlet pressure
Target pressure: 0.5 - 1.0 MPa, 5 - 10 bar (display range: 0 - 1.0 MPa, 0 - 10 bar)
(5) Compressed air filter
(6) Compressed air connection
(7) Stop valve in the "OPEN" position
(6)
(1)
(2)
(3)
(4)
(5)
(7)

User manual SIPLACE SX1/SX2 4 Setting up and commissioning
From software version SC 706.1 SP1 Version 10/2014 4.2 Infrastructure at the installation location
193
4.2.3 Main power supply
4
Fig. 4.2 - 2 Position of the power supply on the machine
(1) Transformer unit (behind the used tape chute) in the machine frame
(2) Side cover
(3) Lock
(4) Main power switch secured to prevent switching on again
(5) Front cover
(6) Mains connection cable
(3)
(4)
(5)
(1)
(2)
(6)

4 Setting up and commissioning User manual SIPLACE SX1/SX2
4.2 Infrastructure at the installation location From software version SC 706.1 SP1 Version 10/2014
194
4.2.3.1 Danger notes
4
4.2.3.2 Checking the main power supply
Check whether the power supply complies with the prescribed machine specifications (see table
in section 3.2
, page 97).
4
4.2.3.3 Power supply cable - specification
The following specifications apply to the power supply cable for the machine:
– 5 x 2.5 mm² for 3 x 380 V~ / 3 x 400 V~ / 3 x 415 V~ for a cable length of up to 20 meters to
the machine mains power cable. Over 20 meters cable 5 x 4 mm².
– 5 x 4 mm² for 3 x 200 V~/ 3 x 208 V~ / 3 x 220 V~ / 3 x 230 V~ for a cable length of up to 10
meters to the machine mains power cable. Over 10 meters cable 5 x 6 mm².
The color coding for the wires will depend on the country in which the system is operated.
4
4
DANGER
Dangerous voltage levels!
The machine is supplied with 3 x 200 V~, 3 x 208 V~, 3 x 220 V~, 3 x 230 V~, 3 x 380 V~,
3 x 400 V~ or 3 x 415 V~ ± 5 %, 50/60 Hz mains voltage. This means that some parts of
the system carry potentially lethal voltages - even when switched off at the main power
switch.
Incorrect handling of this machine can therefore result in death or severe injury or consid-
erable damage to equipment.
Always follow the applicable accident prevention and DIN regulations (particularly EN
60204, part 1 or IEC 60204, part 1) and the applicable regulations in your own coun-
try.
The covers over the power supply unit may ONLY be opened by appropriately quali-
fied and trained personnel.
PLEASE NOTE
Load peaks in power supply
For technical reasons, load peaks occur in the power supply.
Please contact your power company to clarify the mains impedance, if necessary.
WARNING
Clear marking of electrical leads!
The electrical leads to each individual machine and to the options installed (e.g. WPC5/
WPC6) must be clearly labeled and easily assignable.
The regulations of the country in which the machine is operated apply.