00196962-04-BA-SX12-V2-EN.pdf - 第51页
User manual SIPLACE SX1/SX2 2 Operational safety From software version SC 706.1 SP1 Version 10/2014 2.2 Warning labels 51 2.2.7 High temperatures on th e Head Control Unit (HCU) 1 in fig. 2.2 - 10 , temperature label, it…

2 Operational safety User manual SIPLACE SX1/SX2
2.2 Warning labels From software version SC 706.1 SP1 Version 10/2014
50
2.2.6 Warning label on the EMERGENCY STOP buttons
2
W209 in fig. 2.2 - 9, item no. 03009349-01 (quantity per machine: 2)
2
2
Fig. 2.2 - 9 Warning label W209 on the EMERGENCY STOP buttons
W209, article no. 03009349-01
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
For Australia, Canada, Mexico and USA, warn-
ing label W209 is affixed to the extension kit in-
stead of the yellow ring on the EMERGENCY
STOP buttons.
W 209

User manual SIPLACE SX1/SX2 2 Operational safety
From software version SC 706.1 SP1 Version 10/2014 2.2 Warning labels
51
2.2.7 High temperatures on the Head Control Unit (HCU)
1 in fig. 2.2 - 10, temperature label, item no. 03031926-01 (2 to 4, depending on head configura-
tion).
2
Fig. 2.2 - 10 Temperature label on the Head Control Unit (HCU)
2
RISK OF BURNS FROM HIGH TEMPERATURES!
The housing of the Head Control Unit (HCU) can become hot during contin-
uous operation.
Take care when touching the Head Control Unit (HCU).
(1)
(1)

2 Operational safety User manual SIPLACE SX1/SX2
2.2 Warning labels From software version SC 706.1 SP1 Version 10/2014
52
2.2.8 "Head crash" label on the IC camera of the TwinStar
"Head crash" label in fig. 2.2 - 11, item no. 03015392-02
(quantity per machine: maximum 2)
2
Fig. 2.2 - 11 "Head crash" label on the IC camera of the TwinStar
(1) "Head crash" label on the IC camera of the TwinStar
WARNING RISK OF HEAD CRASH 2
When changing the placement head from a TwinStar/VHF to a
SpeedStar, the SpeedStar collides with the camera housing.
Dismantle the stationary component cameras of type 33, 55 x 45,
and type 25, 16 x 16 for the TwinStar.
(1)