User Manual SIPLACE 80S-20/F4 6 Vision functions
Software version SR.406.xx 02/2000 Issue US 6.6 Test Component
329
The following button appears when this option is selected. 6
Abb. 6.6.44 ‘Test component’ menu, ‘Set component type’ option
Select this option if centering errors occur with standard lighting. These 4 selection
options enable you to match the illumination perfectly to the component to be placed. All these
options provide specific combinations of the flat, average, and steep methods of illumination. 6
6
Mouse functions 6
Å Use the mouse to highlight the component type.
Å Click on ‘OK’ to confirm your input. The option box will close, and you will return to the ‘Test
component’ menu.
Å Click on ‘Cancel’ to leave the option box without making any changes.
6
6 Vision functions User Manual SIPLACE 80S-20/F4
6.7 Guidelines for Describing Package Forms Software version SR.406.xx 02/2000 Issue US
330
6.7 Guidelines for Describing Package Forms
6.7.1 Transfer of Package Form Data and the Package Form Interpreter
If a package form is transferred to the station without an .SST file, the package form interpreter
will make certain settings to enable the package form to be measured in accordance with the
package form description. 6
6
Fig. 6.7 - 1 Transfer of package form data without package form manipulation
In SIPLACE automatic placement machines, the package form interpreter is located in the ma-
chine controller. The communication module transfers the signals for controlling the lighting from
the MC to the cameras. 6
Tasks of the Package Form Interpreter 6
Automatic selection of suitable measuring modes
Automatic selection of the measuring parameters
Differentiation between cubic/not cubic
Automatic setting of the lighting
LC
Package form library
Describe package for & components
Assign nozzles
Select cameras
.OGF
Package form interpreter
SC
MVS
Automatic selection of meas. modes
Automatic lighting selection
Hard disk
GF manipulator
User Manual SIPLACE 80S-20/F4 6 Vision functions
Software version SR.406.xx 02/2000 Issue US 6.7 Guidelines for Describing Package Forms
331
The package form interpreter processes standard components and automatically identifies spe-
cial components. Under certain circumstances, other components have to be post-processed. If
the package form settings have to be manipulated, these changes will be stored in the .SST file
and transferred back to the line computer. 6
6
Fig. 6.7 - 2 Transfer of package form data with package form manipulation
If a package form is transferred to the station with the .SST file, then the settings for the .SST file
for measuring the package form will also be transferred. The package form interpreter will remain
inactive. 6
LC
Package form library
Describe package form & components
Assign nozzles
Select cameras
.OGF
Package form interpreter
SC
MVS
Automatic selection of meas. modes
Automatic lighting selection
Hard disk
GF manipulator
.SST
Important note:
Manipulation of components at the station must be the exception and not the rule
In general, only a few components have to be changed.