00191913-01.pdf - 第64页
1 Introduction User Manual SIPLACE 80S-20/F4 1.15 Overview of the modules - PCB conveyor Software version SR.406.xx 02/2000 Issue US 62 1 1 PCB transpo rt heigh t 830 mm ± 15 mm (s tandard) 900 mm ± 15 mm (opti on) 930 m…

User Manual SIPLACE 80S-20/F4 1 Introduction
Software version SR.406.xx 02/2000 Issue US 1.15 Overview of the modules - PCB conveyor
61
The conveyor belts are driven by DC motors. The lifting table near the center conveyor clamps the
PCBs in position. The width of the PCB conveyor can be adjusted, either using the menu or from
the line computer. 1
1.15.2 Technical data – single conveyor
1
1.15.3 Technical data – dual conveyor
1
PCB format
50mm x 50mm to 460mm x 460mm
2" x 2" to 18" x 18"
Optionally:up to 508mm x 460mm
up to 20" x 18 "
PCB thickness 0.5mm to 4.5mm
Max. PCB warpage
On top: 4.5mm - PCB thickness
On bottom: 0.5mm + PCB thickness
Clearance on PCB underside 25mm (standard), 40mm (option)
PCB transport height
830mm ± 15mm (standard)
900mm ± 15mm (option)
930mm ± 15mm (option)
950mm ± 15mm (SMEMA: optional)
Fixed conveyor edge Right (standard), left (optional)
Type of interface Siemens (standard), (SMEMA: optional)
Component-free handling edge 3mm
PCB changeover time 2.5 s
PCB format
50mm x 50mm to 460mm x 216mm
2" x 2" to 18" x 8.5"
Optionally:up to 508mm x 216mm
up to 20" x 8.5 "
PCB thickness 0.5mm to 4.5mm
Max. PCB warpage
On top: 4.5mm - PCB thickness
On bottom: 0.5mm + PCB thickness
Clearance on PCB underside 25mm (standard), 40mm (option)

1 Introduction User Manual SIPLACE 80S-20/F4
1.15 Overview of the modules - PCB conveyor Software version SR.406.xx 02/2000 Issue US
62
1
1
PCB transport height
830mm ± 15mm (standard)
900mm ± 15mm (option)
930mm ± 15mm (option)
950mm ± 15mm (SMEMA: optional)
Fixed conveyor edge Right (standard), left (optional)
Type of interface Siemens (standard), (SMEMA: optional)
Component-free handling edge 3mm
PCB changeover time 2.5 s
Components on each conveyor Synchronous: same or different, asynchronous: same
PCB width on each conveyor Synchronous: different, asynchronous: same
Ink spot recognition Synchronous: not possible, asynchronous: possible
Automatic width adjustment Synchronous: not possible, asynchronous: possible

User Manual SIPLACE 80S-20/F4 2 Operational safety
Software version SR.406.xx 02/2000 Issue US 2.1 Safety instructions
63
2 Operational safety
2.1 Safety instructions
2.1.1 Conventions for the use of hazard symbols
This User Manual contains notes that must be observed to guarantee your personal safety and to
avoid damage to equipment. These notes are highlighted by warning triangles and are indicated
as follows according to the level of risk: 2
2
DANGER or 2
as used in this User Manual means that death, severe injury or considerable damage to equip-
ment may occur if the danger instructions are not followed. 2
2
WARNING or 2
as used in this User Manual means that death, severe injury or considerable damage to equip-
ment may occur if the warning instructions are not followed. 2
2
CAUTION or 2
as used in this User Manual means that slight injury or damage to equipment may occur if the cau-
tion instructions are not followed. 2
2
PLEASE NOTE 2
as used in this User Manual provides information on the product or indicates a part of the User
Manual that requires particular attention. 2
2.1.2 Qualified personnel
Qualified or adequately trained personnel means that these people are familiar with the setting up,
operation and maintenance of automatic placement systems and add-on devices and are suitably
qualified, e.g. 2
– have been trained, instructed or authorized to switch on and off, isolate, earth and identify elec-
trical circuits and system components in accordance with normal safety standards.