00191913-01.pdf - 第41页

User Manual SIPLACE 80S-20/F4 1 Introduction Software version SR.406.xx 02/2000 Issue US 1.7 Electrical and pneumatic connection points 39 DANGER The place ment machi ne is suppli ed with 3 x 400 V or 3 x 208 V (US ver s…

100%1 / 564
1 Introduction User Manual SIPLACE 80S-20/F4
1.7 Electrical and pneumatic connection points Software version SR.406.xx 02/2000 Issue US
38
1.7 Electrical and pneumatic connection points
1
Fig. 1.7 - 1 Electrical and pneumatic connection points on the machine
(1) Compressed air unit
(2) Connection for compressed air line
(3) Main power filter Z1
(4) Hole for power cable
(5) Service socket
(6) Compressed air connection for changeover table
(7) Power supply connection for changeover table
(8) Communications connection for changeover table
(9) LAN supply in control unit
(10) Main switch
User Manual SIPLACE 80S-20/F4 1 Introduction
Software version SR.406.xx 02/2000 Issue US 1.7 Electrical and pneumatic connection points
39
DANGER
The placement machine is supplied with 3 x 400 V or 3 x 208 V (US version) ± 5 %, 50/60 Hz
mains voltage. Consequently parts of these systems carry potentially lethal voltages, even when
switched off at the main switch. Incorrect handling of this placement machine can therefore result
in death or severe injury, or considerable damage to equipment. 1
WARNING
NEVER detach compressed air lines while they are still pressurized. Risk of injury. 1
1 Introduction User Manual SIPLACE 80S-20/F4
1.8 Technical data – ratings Software version SR.406.xx 02/2000 Issue US
40
1.8 Technical data – ratings
1.8.1 Technical data – electrical ratings
1.8.2 Technical data – compressed air supply
1.8.3 Technical data – compressed air specification
Maximum particle size by density, based on ISO/DIS 8573-1 (class 1) 1
1.8.4 Technical data – noise emissions
1.8.5 Technical data – permissible ambient factors
Supply voltage 3 x 400 VAC ± 5 %; 50/60 Hz (Europe)
3 x 208 VAC ± 5 %; 50/60 Hz (U.S.A.)
Fuses 3 x 16 A (3 x 400 VAC, 3 x 208 VAC)
Total connected load 5 kVA
Total power 2,9 kW (S-20), 1,9 kW (F
4
)
Power failure up to 20 msec
Compressed air pressure Min. 5.5 bar (S-20), min 6 bar (F
4
), max. 8 bar
Compressed air consumption 400 Nl/min.
Operating pressure 5.2 bar (fixed)
Particle size 0.1 µm
Particle density 0.1 mg/m³
Maximum oil content (class 1) Particle density 0.01 mg/m³
Pressure dewpoint (class 4) Dewpoint +
Emission value at a workstation (L
pAc
) 71 dB (A) DIN EN ISO 11204 (i)
Sound power level (L
WAc
) 85 dB (A) E-DIN EN ISO 3744 (i) 001-0307
Room temperature Between 15°C and 35°C
Atmospheric humidity 30 to 75%
(but no higher than 45% on average in order to prevent
any possibility of condensation on the machine).