00191913-01.pdf - 第429页

User Manual SIPLACE 80S-20/F4 10 Component handling Software version SR.406.xx 02/00 US Edition 10.2 Technical data for the feeder modules 427 10.2.10 Component disposal module ( 80F 4 ) 10 Fig. 10.2 - 10 Component dispo…

100%1 / 564
10 Component handling User Manual SIPLACE 80S-20/F4
10.2 Technical data for the feeder modules Software version SR.406.xx 02/00 US Edition
426
10.2.9 72mm S module (80F
4
)
10
Fig. 10.2 - 9 72 mm S module
Item no. 00141097-xx
Width 90 mm
Tracks per module 1
Maximum number of modules 2 x 6
Magazine capacity for 7" reels Approx. 2000
Reel diameter Up to 381 mm
Feeding stroke (variable) 4 to 72 mm (in 4 mm increments)
Cycle time 60 ms ± 5 ms for a feeding interval of 8 mm
Main power supply 30 VDC
User Manual SIPLACE 80S-20/F4 10 Component handling
Software version SR.406.xx 02/00 US Edition 10.2 Technical data for the feeder modules
427
10.2.10 Component disposal module (80F
4
)
10
Fig. 10.2 - 10 Component disposal module
10
Article number 00141200-xx
Width 54mm
Tracks per module 1
Feeder locations occupied 2
Component range up to 27mmx27mm for a 30mmx30mm pocket size
up to 13mmx13mm for a 15mmx30mm pocket size
Maximum component height 14mm
Transport distance (adjustable) 20mm for a 15mmx30mm pocket size
36mm for a 30mmx30mm pocket size
Power supply 30 V-
10 Component handling User Manual SIPLACE 80S-20/F4
10.2 Technical data for the feeder modules Software version SR.406.xx 02/00 US Edition
428
10.2.10.1 Functional description
The component disposal module has essentially the same structure as a feeder. The only differ-
ence is that it has an empty tape, rather than a component tape. Faulty components can be placed
in the pockets of this empty tape without damaging them. This means that these components can
subsequently be manually checked, repaired and thus reused. The advantage of the disposal con-
veyor is that the operator can remove the separated components without having to interrupt the
placement process. Once all the pockets on the conveyor belt are full, a message appears on the
monitor, prompting the operator to remove the components. 10
10.2.10.2 System requirements
The following system requirements must be fulfilled in order to use the component disposal mod-
ule: 10
Line software version 501.01 or later
Station software version 405.01 or later
Feeder table software version 3.09 or later
PLEASE NOTE:
The component disposal module must be configured on the line computer and activated on the
station computer. 10
10.2.10.3 Conditions for disposal of components using the component disposal module
A component is placed on the disposal conveyor if the following conditions are fulfilled: 10
10
The component type to be disposed of must be included in the set-up on the line computer.
The component must be identified for return.
Components to be disposed of from a carrier tray must already have been wetted with flux in
the dip fluxer. If this is not the case, they will be returned to the tray.
10
10