4.2.2 Station Interface for Teaching Component Shapes
4-3: No authorization for geometric programming in station SW
Legend
1. Access to geometry teaching is blocked in the
access privileges management for all
component shapes. This can be seen by the
padlock icon shown.
The diagram shows the operating level
Operator
for CS testing and limited CS teaching.
4-4: Centering steps for optical recognition of a SOxx
The operating level
Operator
in the station SW
gives the teaching/testing person protected
(limited) access to the CS data.
However, access to the illumination algorithm
parameters and measurement results is provided.
1. Access to the geometric data remains
protected.
2. The menu item
Teach position
is only
displayed when a pickup error occurs.
This sub-menu is not included in the normal
CS teaching menu.
This entry initiates temporary teaching of the
pickup position and pickup angle, provided a
new job has not been defined.

User Interface
Operating Level " Supervisor" SIPLACE Pro Component Shape Editor
Student Guide SIPLACE Vision (Customer)
User Interface Edition 12/2008 EN
22
4.3 Operating Level " Supervisor"
If an operator level, which allows full access to CS programming data for personnel, is set for SIPLACE
Pro (Supervisor; Service), the persons concerned will have full access to all the CS programming menus
in SIPLACE Pro and at the station.
A geometry change which is programmed with SIPLACE Vision also affects machines with the ICOS
Vision system.
4.3.1 SIPLACE Pro Component Shape Editor
4-5: Complete programming privileges for a component shape in SIPLACE
Pro
The adjacent diagram shows full access to the CS
programming data on Service or Supervisor level
in SIPLACE Pro.

User Interface
Station Interface for Teaching Component Shapes Operating Level " Supervisor"
Student Guide SIPLACE Vision (Customer)
Edition 12/2008 EN User Interface
23
4.3.2 Station Interface for Teaching Component Shapes
4-6: Component selection menu at the station with programming privileges
for geometry
1. Select the component to be measured from
the list of components for the predefined
setup.
2. By selecting the presentation angle you can
define the angular position of the component
shape for measurement. This setting is NOT
only available for Twin Head.
3. The pickup procedure is triggered by the
Pickup Component button.
The component can then be measured by the
component camera.
The diagram shows the operating level Supervisor
for CS testing and teaching.
4-7: Centering steps for SOxx
The station user interface shown in the adjacent
figure displays the operating level Service. This is
also shown in the teach menu at the station and
allows full access to the CS programming data,