SIPLACE Vision Customer_en.pdf - 第23页
User Interface Station Interface for Teaching Component Shape s Operating Level " Supervisor" S tudent Guide SIPLACE Vision (Customer) Edition 12/2008 EN User Interface 23 4.3.2 St ation Interface for T eaching…

User Interface
Operating Level " Supervisor" SIPLACE Pro Component Shape Editor
Student Guide SIPLACE Vision (Customer)
User Interface Edition 12/2008 EN
22
4.3 Operating Level " Supervisor"
If an operator level, which allows full access to CS programming data for personnel, is set for SIPLACE
Pro (Supervisor; Service), the persons concerned will have full access to all the CS programming menus
in SIPLACE Pro and at the station.
A geometry change which is programmed with SIPLACE Vision also affects machines with the ICOS
Vision system.
4.3.1 SIPLACE Pro Component Shape Editor
4-5: Complete programming privileges for a component shape in SIPLACE
Pro
The adjacent diagram shows full access to the CS
programming data on Service or Supervisor level
in SIPLACE Pro.

User Interface
Station Interface for Teaching Component Shapes Operating Level " Supervisor"
Student Guide SIPLACE Vision (Customer)
Edition 12/2008 EN User Interface
23
4.3.2 Station Interface for Teaching Component Shapes
4-6: Component selection menu at the station with programming privileges
for geometry
1. Select the component to be measured from
the list of components for the predefined
setup.
2. By selecting the presentation angle you can
define the angular position of the component
shape for measurement. This setting is NOT
only available for Twin Head.
3. The pickup procedure is triggered by the
Pickup Component button.
The component can then be measured by the
component camera.
The diagram shows the operating level Supervisor
for CS testing and teaching.
4-7: Centering steps for SOxx
The station user interface shown in the adjacent
figure displays the operating level Service. This is
also shown in the teach menu at the station and
allows full access to the CS programming data,
with all write privileges.

User Interface
Editing the Camera Image (for all Vision Menus) Station Interface for Teaching Component Shapes
Student Guide SIPLACE Vision (Customer)
User Interface Edition 12/2008 EN
24
4.4 Editing the Camera Image (for all Vision Menus)
The station SW has a section for SIPLACE Vision tasks e.g. for displaying the optical processes at the
station to perform machine checks, for optical recognition of the PCB or component position and quality.
This display area can only be accessed in operating level
Line engineer
.
Displaying the camera image
In the case of recognition problems, this "Vision monitor" can be enabled instead of the station computer
(press "Alt" 8 for placement area 1 (PA1) or "Alt" 9 for PA2 to activate). This also applies for the powering
up procedure before the start button is pressed for the first time. The procedures for "measuring
component table position", feeder position recognition etc. are then shown on the camera image.
Halt stops the optical centering images. However, the machine does NOT stop the reference or
placement run.
The last 10 images in the process can be analyzed with the back/forwards button.
This shows the interface for optical centering of a
component during the placement procedure.
The top left of the image shows the centering
quality as a green bar. If centering errors occur
(red bar) the image will be saved for subsequent
analysis.