Calibration
HLGB-10301-01
PWB Camera Light Calibration
SHEET
2/3
4 Select jig No. of light calibration jig from the
list box.
5 Move the PWB camera to above the
calibration plate jig.
1. Click the XY button on the PWB
Camera Light screen.
XY Axis screen is displayed.
2. Click the Jog Move button.
3. Jog move the PWB camera to above
the calibration plate jig.
4. Click the Return button to return to
the PWB Camera Light screen.
6 Click the Calibration Start button.
“Put jig under PWB camera” is displayed on the
message screen.
Calibration
HLGB-10301-01
PWB Camera Light Calibration
SHEET
3/3
7 Place the light calibration jig on the
calibration plate jig below the PWB camera.
Place it so that center of the PWB camera light
is on the center of light calibration jig.
8 Press the [START] button on the operation
panel.
PWB camera light calibration is started.
After a few minutes, the calibration ends, and Lv1
values from level 1 to 8 and Gap value are displayed
on the PWB Camera Light screen.
9 Check the Gap values of Level 1 to 8.
It is normal if the Gap value is within 0 to 3.
10 Click the Save button.
The Gap values of Lvl 1 to 8 are saved and the PWB
Camera Light screen closes.
11 Remove the light calibration jig.
PWB camera
PWB Camera
Light
Light Calibration jig
(Gloss face is downward)
Calibration
HLGB-10302-01
Fixed Camera Light Calibration
SHEET
1/3
Fixed Camera Light Calibration
(Upper LightMiddle LightLower LightCoaxial Light)
Calibration procedure of fixed camera upper light will be described here as an example.
Also perform calibrations of fixed camera middle light/fixed camera lower light/fixed camera coaxial
light by the same procedure.
[Necessary jigs]
Fixed camera light calibration jig
[Procedure]
1 Display a Fixed Camera Light screen.
1. Click the Light Calibration button on
the CALIBRATION screen.
Light Calibration screen is displayed.
2. Click the Fixed Camera Upper Light
button on the Light Calibration
screen.
Fixed Camera Upper Light screen is displayed.
When performing calibrations of fixed camera
middle light/fixed camera lower light/fixed
camera coaxial light, click the associated
button to open each calibration screen.
Fixed camera light
calibration jig