MAN00000772_SI-G200BB_SVCPDFA.pdf - 第703页

XY axis movable parts RPGB-1 1301-01 Change Procedure for Y Axis LM-GUIDE SEET 1 / 9 Change Procedure for Y Axis LM-guide [Necessary jigs] ■ Hold JIG ■ Thickness ga uge (0.0 1mm, 0.02m m) ■ Grease gun CAUTION LM-guide is…

100%1 / 712
XY axis movable parts
RPGB-11201-01
Change Procedure for
X Axis
LM-GUIDE
SEET
7/7
12, Connect the X-axis motor power connector (XM)
13, Installation the Head Unit;
and setup & Calibration
Refer to the following
A-head RPF-10103-01
B-Head RPGB-10301-01
XY axis movable parts
RPGB-11301-01
Change Procedure for
Y Axis
LM-GUIDE
SEET
1/9
Change Procedure for Y Axis LM-guide
[Necessary jigs]
Hold JIG
Thickness gauge (0.01mm, 0.02mm)
Grease gun
CAUTION
LM-guide is 1set in 2rail. (Right and Left)
Exchange of right and left at the same time
standard work is to exchange the LM guide of right and left one each by turns
Working operation is same time as FRONT side and REAR side
[Disassembly of LM-guide]
1, Prior work
1-1 Remove the Cassette bank chenger of M/C
1-2 Stop the M/C. turn off the power switch
1-3 Remove the Shooter cover
1-4 X-Axis move to Y-Axis end position
1-5
Remove the Y-axis motor power connector (YM)
XY axis movable parts
RPGB-11301-01
Change Procedure for
Y Axis
LM-GUIDE
SEET
2/9
2, Fixed the screw in X-axis and slide block of
a LM-guide, unscrew it,
(slide block of front side and rear side)
POINT
keep the balance of the X-axis and let overweight to
ball screw reduce
Head position is move to the side that does not exchange
a LM guide is BEST
Do not remove right and left at the same time
Be careful not to drop a washer
3, Remove the LM-guide
(LM-guide of right and left)
[Reassembly of LM-guide]
1, Prior work
1-1 Apply grease into new LM-guide
POINT
Application grease (AFC-grease Maker: THK)
use a suitable amount
Be careful to not apply much quantity
Be careful of slide block come off and ball fall
1-2 Cleaning of the LM-guide installation surface
POINT
Polish an installation surface with an oil stone
Wipe dust at clean cloth