MAN00000772_SI-G200BB_SVCPDFA.pdf - 第206页

Calibration HLGB-10302-01 Fixed Camera Light Calibrat ion SHEET 2/3 2 Select jig No. of fixed camera light calibration jig from the list box. 3 Click the Calibration S tart button. “Install calibration jig for fixed ligh…

100%1 / 712
Calibration
HLGB-10302-01
Fixed Camera Light Calibration
SHEET
1/3
Fixed Camera Light Calibration
(Upper LightMiddle LightLower LightCoaxial Light)
Calibration procedure of fixed camera upper light will be described here as an example.
Also perform calibrations of fixed camera middle light/fixed camera lower light/fixed camera coaxial
light by the same procedure.
[Necessary jigs]
Fixed camera light calibration jig
[Procedure]
1 Display a Fixed Camera Light screen.
1. Click the Light Calibration button on
the CALIBRATION screen.
Light Calibration screen is displayed.
2. Click the Fixed Camera Upper Light
button on the Light Calibration
screen.
Fixed Camera Upper Light screen is displayed.
When performing calibrations of fixed camera
middle light/fixed camera lower light/fixed
camera coaxial light, click the associated
button to open each calibration screen.
Fixed camera light
calibration jig
Calibration
HLGB-10302-01
Fixed Camera Light Calibration
SHEET
2/3
2 Select jig No. of fixed camera light
calibration jig from the list box.
3 Click the Calibration Start button.
“Install calibration jig for fixed light. Press [START]
to start light calibration” is displayed on the message
screen.
4 Install the fixed camera light calibration jig to
the fixed camera.
5 Fixed camera upper light calibration is started.
1. Press the [START] button on the operation panel.
Calibration is started.
Fixed camera
light calibration jig
Fixed camera
Calibration
HLGB-10302-01
Fixed Camera Light Calibration
SHEET
3/3
After a few minutes, the calibration ends, and
“Remove calibration jig for fixed light” is
displayed on the message screen.
2. Remove the fixed camera light
calibration jig and click the OK
button.
When subsequently performing calibrations of
fixed camera middle light/fixed camera lower
light/fixed camera coaxial light, it is
unnecessary to remove the jig.
6 Click the Save button.
The Gap values of Lvl 1 to 8 are saved and the Fixed
Camera Upper Light screen closes.
7 Perform calibrations of fixed camera middle
light/fixed camera lower light/fixed camera
coaxial light by the same procedure.