Calibration HLGB-10313-01 Mount Accuracy Calibration SHEET 10/1 1 2. Click the OK button on th e confirmation window . The next confirmation window displays “Head at opposite position will be moved to noninterference are…

100%1 / 712
Calibration
HLGB-10313-01
Mount Accuracy Calibration
SHEET
9/11
2. Display OPERATION SETUP to check
that settings are as follows.
Motion Mode: Normal Opr.
Parts-Out Mode: Stop
Pre-Pick Mode: OFF
Auto Recovery: OFF
Parts Alternate: OFF
Stop Mode: Cycle Stop
3. Display Motion Setup (Unit) screen to
check that settings are as follows.
Nozzle Escape Detect: Yes
Display result of recognition: No
Unload PWB First: Turned off
3 Press [START] button on the operation
panel and fit parts onto the simple
measuring glass PWB.
Fitting operation is performed for one cycle, and then
the unit stops.
Make sure the wrong pickup or pickup error
does not occur.
4 When fitting is completed without error,
display the accuracy correction screen.
1. Click in an order of M/C SETUP menu
M/C MAINTENANCE tab
Calibration button.
A confirmation window to clear machine data is
displayed.
Calibration
HLGB-10313-01
Mount Accuracy Calibration
SHEET
10/11
2. Click the OK button on the
confirmation window.
The next confirmation window displays “Head at
opposite position will be moved to
noninterference area. Press the [START] button if
you are really OK.”
3. Press the [START] button on the
operation panel.
CALIBRATION screen is displayed.
5 Click the Mount accuracy calibration button.
Mount accuracy calibration screen is displayed.
6 Make sure the message “Global
transcription calibration” is displayed in the
Calibration contents field, and then click the
Start calculation calibration data button.
Calibration
HLGB-10313-01
Mount Accuracy Calibration
SHEET
11/11
Wait until the parts recognition by the PWB camera
ends.
7 Check the displayed result and, if the
correction value needs to be applied, click
the Apply button.
When the Cancel button is clicked, the process ends
without executing the calibration.
When the calculation result is 3Sigma <
±40[µm] and Avg < 10[µm], the catalog SPEC
(±60[µm] CPK > 1.0) is satisfied.