MAN00000772_SI-G200BB_SVCPDFA.pdf - 第80页
Install Tray Unit (Including machine modification) SHEET 41/73 WKGB-10104-03 Installing Tray Unit (Including machine modification) [Adjustment of cassette floating detection sensor] [Necessary jig and T ools] ・ Feed adju…

SHEET
Cassette specification is different from tray
specification in jig hole to be used.
Holes on the front are for cassette specification
and holes on the back are for tray specification
with the optical axis adjustment jig being placed
on the cassette table.
5. When putting optical axis adjustment jig on
the supply No. 101, 120 and 140, check that
the sensor is turned ON.
6. When shielding the area sensor by hand,
check that the sensor is turned OFF on the
I/O monitor screen.
1 ) Remove the optical axis adjustment
jig.
2 ) Click in an order of MANUAL menu
I/O tab Serial I/O button
Input tab.
Serial I/O screen is displayed.
3 ) When shielding the area sensor by
hand, check that the sensor is turned
OFF.
For tray specification
For cassette specification
Install Tray Unit (Including machine modification)
40/73
WKGB-10104-03
Installing Tray Unit
(Including machine modification)

Install Tray Unit (Including machine modification)
SHEET
41/73
WKGB-10104-03
Installing Tray Unit
(Including machine modification)
[Adjustment of cassette floating detection sensor]
[Necessary jig and Tools]
・Feed adjusting Jig
・Cassette float sensor height adjusting Jig
1 Set threshold of the sensor amplifier to 200.
NOTE:
Press the UP,DOW buttons and set the green indication
to 200.
2 Adjust position of the sensor so that the
following conditions are satisfied.
Condition:
When thickness is 5mm. Light receiving level should be
200 or more.
When thickness is 6mm. Light receiving level should be
200 or less.
1. Put the Feed adjusting Jig onto the Z101.
2. Put the Cassette float sensor height adjusting Jig
onto the Feed adjusting Jig.

Install Tray Unit (Including machine modification)
SHEET
42/73
WKGB-10104-03
Installing Tray Unit
(Including machine modification)
3. Adjust position of the projection side sensor head
so that the conditions are satisfied.
4. Put the Feed adjusting Jig and the Cassette float
sensor height adjusting Jig onto the Z117.
5. Adjust position of the light receiving side sensor
head so that the conditions are satisfied.
6. Put the Feed adjusting Jig and the Cassette float
sensor height adjusting onto the Z108.
7. Check position of the sensor so that the conditions
are satisfied.
NOTE:
When the condition of the light receiving level is not
satisfied, please adjustment sensor position again.
Feed adjusting Jig
6 ㎜
5 ㎜
Light axis position