Calibration
HLGB-10306-01
Auto Calibration (Recognition of
Relationship for the Multiple Recognition)
SHEET
4/4
9 End auto calibration.
1. If the recognition of relationship between PWB coordinate and mechanism coordinate has
been performed in advance of this procedure, return the software limit for Y-axis to the
original value.
2. Remove the jig chips, calibration plate, and the jig nozzles.
After ending automatic calibration, perform nozzle changer teaching.
For nozzle changer teaching procedure, refer to “Nozzle Changer Teaching [HLGB-10307-01]”.

Calibration
HLGB-10307-01
Nozzle Changer Teaching
SHEET
1/5
Nozzle Changer Teaching
[Necessary jigs]
• Jig nozzle for nozzle changer
[Procedure]
1 Remove all nozzles from the head.
Do not execute the automatic replacement of
the nozzle when the teaching of the nozzle
changer has not been completed.
2 Attach the nozzle cartridge to the system.
Do not install a nozzle to the nozzle cartridge.
3 Press the [ORG] button on the operation
panel to perform origin position return.
Jig nozzle for nozzle changer
Remove all nozzles
Nozzle cartridge

Calibration
HLGB-10307-01
Nozzle Changer Teaching
SHEET
2/5
4 Move the head clear of the work area.
1. Click in an order of MANUAL menu
AXIS MOTION tab XY button.
XY Axis screen is displayed.
2. Click the Jog Move button in the move
mode.
3. Press the cursor key to move the head
to a position where working is easily
performed.
4. After moving the head, click the
Return button to close the XY axis
screen.
5 Install the jig nozzle for nozzle changer to
the turret No.1.
Attach the jig nozzle so that its notch comes inward of
the turret.
6 Make sure turret No.1 is under the H-axis.
If the position is deviated, move the turret No.1 to
under the H axis on the operation screen for the RT
axis.
Jig nozzle fo
r
nozzle changer