1-44 AKHEMT -ID 3.3.13 Fans Every 3 Months Cleaning Required T ime: 5 minutes Suck dirt and dust from the dust filters with a vacuum cleaner . 10 fans are used in all but only 4 fans are provided with dust filters. Fan (…

1-43
AKHEMT-ID
3.3.12 Control Box Section
Fan (1 place)
Every 3 Months Cleaning
Required Time: 2 minutes
(1) Detach four setscrews fastening the
dust filter.
(2) Suck dirt and dust with a vacuum cleaner.
(3) Attach the dust filter and secure it with
the setscrews.
Fig. 4A34
0605-002
3.3 Inspection, Cleaning, and Lubrication Spots

1-44
AKHEMT-ID
3.3.13 Fans
Every 3 Months Cleaning
Required Time: 5 minutes
Suck dirt and dust from the dust filters with
a vacuum cleaner.
10 fans are used in all but only
4 fans are provided with dust filters.
Fan (Provided with Dust Filter)
(4 places)
Note
Fans with Dust Filters
Fans with Dust Filters
Fig. 4A35
0605-002
3.3 Inspection, Cleaning, and Lubrication Spots

1-45
AKHEMT-ID
4. Maintenance Method
4.1 Cleaning of Vacuum Nozzles
Periodically clean the vacuum nozzles to maintain reliable and stable
component picks and placement.
•
It is advisable that the nozzles be cleaned at least once a week.
•
Change cleaning frequency according to various frequency of use and
accumulation of debris along with certain environmental conditions.
•
When the vacuum suction force weakens or a nozzle constantly fails to
pick or place components, it is required to check the nozzle for debris and
cleanliness.
Do not grasp this part strongly during the
nozzle cleaning.
Otherwise, the nozzle may be damaged.
When it is necessary to hold the nozzle firmly,
try to grasp the collar portion.
When a recognition error occurs frequently,
rub the back of the collar approximately
20 times with a toothbrush.
Fig. 4A43
0602-001
4. Maintenance Method