Erroe ID Error Name, Description, Cause, and Remedy
48010f Device Inspect
Time-Out of Recognition ON Response
-----
480110
Device Inspect
Time Out of Image Capture
-----
480111
Device Inspect
Time Out of Image Capture Cancel
-----
480112
Device Inspect
Error Response of Image Capture Cancel
-----
480113
Device Inspect
Time Out of Recognition Result Response
-----
0602-001
3.6 Component Recognition
3-22
AKHEMT-ID
3.7 Automatic Setup
Table 4C9
Erroe ID Error Name, Description, Cause, and Remedy
490603 Conveyor Width Automatic Adjustment
A PCB exists on the L conveyor.
-----
490604 Conveyor Width Automatic Adjustment
A PCB exists on the R conveyor.
-----
490605 Conveyor Width Automatic Adjustment
A PCB exists on the R conveyor.
-----
490617 Conveyor Width Automatic Adjustment
Software limit
-----
490618 Conveyor Width Automatic Adjustment
There is a PCB on the conveyor.
-----
490619 Conveyor Width Automatic Adjustment
Failed in Program Change Operation (Data Error).
-----
49061a Conveyor Width Automatic Adjustment
Failed in Program Change Operation (Time out).
-----
49061b Conveyor Width Automatic Adjustment
Backup Base zeroing Error.
-----
49061c Conveyor Width Automatic Adjustment
Head Up/Down Axis Zeroing Error.
-----
49061d Conveyor Width Automatic Adjustment
The PCB was detected on the Input conveyor.
Please remove the PCB on an Input conveyor.
49061e Conveyor Width Automatic Adjustment
The PCB was detected on the Cnvr. Positioning 1.
Please remove the PCB on a Cnvr. Positioning 1.
490621 Conveyor Width Automatic Adjustment
The PCB was detected on the Output conveyor.
Please remove the PCB on an Output conveyor.
490690 Conveyor Width Automatic Adjustment
Auto Setup Error (Others).
-----
0609-002
3.7 Automatic Setup
3-23
AKHEMT-ID
Erroe ID Error Name, Description, Cause, and Remedy
490701 Nozzle set up
Nozzle Stocker is not set.
Please check whether it is correctly set to the stocker base.
490702 Nozzle set up
Motor Error Detection.
-----
490703 Nozzle set up
Nozzle Stocker Shutter open/close failed.
There is no oat going up of a nozzle, or please check whether there is any
connection etc. in opening and closing.
490704 Nozzle set up
Nozzle Stocker up/dowon failed.
There is no oat going up of a nozzle, or please check whether there is any
connection etc. in opening and closing.
490705 Nozzle set up
Nozzle existence con rmation has error.
Please check whether there is any difference in stocker arrangement data and real
arrangement.
490706 Nozzle set up
Head nozzle existence con rmation has error.
Please check whether there is any difference in head arrangement data and real
arrangement.
490707 Nozzle set up
There is no free space for nozzle storing.
Please con rm the Stocker arrangement data.
490708 Nozzle set up
There are neither a free space nor a nozzle for nozzle exchange.
Please set up an insuf cient nozzle in Noz stocker.
490709 Nozzle set up
Nozzle exchange abnormal data was found.
Please con rm the nozzle arrangement and the Stocker arrangement data.
49070a Nozzle set up
Nozzle stocker position teaching failed.
Please teach the Noz stocker position again on the instruction screen.
49070b Nozzle set up
Placement Hd / Noz data is not corresponding to the real arrangement.
Please con rm the real arrangement of the head nozzle arrangement data and the
head.
49070c Nozzle set up
Nozzle level teach error Detection.
Please execute the nozzle level teaching again on the nozzle level teach screen,
and con rm there is no unexpected value.
49070d Nozzle set up
The nozzle receipt check went wrong.
Please select a recognition image and choose the existence of a nozzle.
0602-001
3.7 Automatic Setup