4OM-1345-009_w.pdf - 第179页
3-29 AKHEMT -ID Erroe ID Error Name, Description, Cause, and Remedy 500d01 Comp. Missing (Sensor) After Chuck ----- 500e01 Comp. Missing (Sensor) Before Mount ----- 0602-001 3.10 Pickup Error

3-28
AKHEMT-ID
3.10 Pickup Error
Table 4C12
Erroe ID Error Name, Description, Cause, and Remedy
500101 Comp. Missing (Sensor)
There is a possibility that the picked comps. have fallen on the feeder and please
confi rm it.
500102 Comp. Missing (Sensor)
There is a possibility that the picked comps. have fallen on the feeder and please
confi rm it.
500201 Vacuum Sensor Error
-----
500301 Comp. Missing (Recog)
There is a possibility that the picked comps. have fallen on the feeder and please
confi rm it.
500401 Comp. Recog Error
-----
500501 Shortage of Component
Shortage of Component
-----
500502 Feeder Reload Stop
Feeder Reload Stop (Splicing)
-----
500601 V.Bend Detection Error
-----
500701 Shortage of Component (Alternated Feeder)
-----
500a01 Auto Recovery Pause
Attach the new comp. And press [READY]. Then, press [START] button to re-start.
-----
500a02 Auto Recovery Pause
Quick recovery stop
-----
500c01 Comp. Vertical (Sensor)
-----
0609-002
3.10 Pickup Error

3-29
AKHEMT-ID
Erroe ID Error Name, Description, Cause, and Remedy
500d01 Comp. Missing (Sensor) After Chuck
-----
500e01 Comp. Missing (Sensor) Before Mount
-----
0602-001
3.10 Pickup Error

3-30
AKHEMT-ID
3.11 Automatic Operation Error
Table 4C13
Erroe ID Error Name, Description, Cause, and Remedy
510101 Auto Run Error
API Error
Please push the [emergency stop] button and return.
510201 Auto Run Error
Pattern program error
Please modify the pattern program.
510202 Auto Run Error
Component Library
Please modify the comp. Library.
510203 Auto Run Error
Operation Mode Error
-----
510204 Auto Run Error
The system setting data is abnormal.
-----
510301 Auto Run Error
JOB time-out during processing.
Please push the [emergency stop] button and return.
510302 Auto Run Error
JOB control Error
-----
510501 Auto Run Error
The recognition result response Error. (Before placement)
-----
510502 Auto Run Error
The recognition result response Error. (After placement)
-----
510601 Auto Run Error
Feeder Alarm
-----
510602 Auto Run Error
Feeder Error (Feed Timeout)
-----
510603 Auto Run Error
Pickup Error
-----
0602-001
3.11 Automatic Operation Error