1-30-1 AKHEMT -ID 0712-001 3.3 Inspection, Cleaning, and Lubrication Spots T ape Guide Fluorine Sheet, Urethane Clamp Every Y ear Replacement (1) Remove four screws and detach the tape guide. (2) Attach the cutter unit f…

1-30
AKHEMT-ID
WARNING
Pay close attention to the cutter blade during the maintenance
work.
·
Lack
of attention will result in a hand injury, etc.
·
Be
suretoattachthexingjigtothecutunitduringthe
maintenance work for safety purposes.
Tape Guide
Flat Ring
Every 3 Months Replacement
(1) Remove four screws and detach the tape guide.
(2) Use the inner holes of the cutter unit fixture with the tape clamp being closed and attach the jig
with the bent portion being directed upward.
Attachment Position of Cutter Unit Fixture Attachment Condition of Replacement Jig
(3) Cut the used flat ring with a cutter on market and detach it.
(4) Attach a new flat ring to the flat ring replacement jig.
(5) Place the flat ring replacement jig on the roller on the oscillating side (outside of the machine),
push down the flat ring, and insert it into the groove of the roller on the oscillating side.
Required Time: 10 minutes
When the tape guide is
detached or attached,
be sure to keep the Y-axis
linear scale free of nicks
and scratches.
Notice
Fig. 4A19-3
CAUTION
Whilecuttingtheatringwithacutteronmarket,handlethe
cutter with care to avoid getting hurt.
0712-003
3.3 Inspection, Cleaning, and Lubrication Spots

1-30-1
AKHEMT-ID
0712-001
3.3 Inspection, Cleaning, and Lubrication Spots
Tape Guide
Fluorine Sheet, Urethane Clamp
Every Year Replacement
(1) Remove four screws and detach the tape guide.
(2) Attach the cutter unit fixture with the bent portion being
directed downward.
Attachment Position of Cutter Unit Fixture
(3) Replace the fluorine sheet and the urethane clamp.
After the fluorine sheet has been replaced, activate the
cutter without the tape threaded through and cut the
fluorine sheet.
Refer to "4.3 Replacement of Fluorine Sheet and Urethane
Clamp" for the replacement procedure.
Required Time: 5 minutes
Reference
Note
Fig. 4A19-4

1-31
AKHEMT-ID
0811-003
3.3 Inspection, Cleaning, and Lubrication Spots
3.3.7 Head Section
Linear Measure Sensors
(Light Emitter and Receiver)
Every Day Cleaning
Required Time: 5 minutes
If sebum and oil, etc., adhere to the surface
of the linear measure sensor, wipe them
off with a cotton swab soaked in absolute
ethanol.
Nozzle U/D Linear Guides (NL Axes)
(2 places)
Every Month Cleaning and Lubrication
(DAPHNE EPONEX GREASE No. 1)
Required Time: 5 minutes
(1) Wipe off the old grease with a rag and
apply a small amount of new grease
with a syringe.
(2) To smooth out the grease, move the
NL axis up and down by 10 mm
through a manual alignment operation
(inching operation).
(3) Wipe off excess grease.
Take ample care not to leave
any waste threads after
cleaning.
Use No. 18 (green) nozzle.
No.18
Note
Notice
Notice
Diffusion Plate
Every Month Cleaning
Required Time: 2 minutes
(1) Store all nozzles in the nozzle stocker
(housing) through window navigations.
(2) Wipe the diffusion p late with a dry
lens cleaning cloth.
Sebum or oil should not
adhere to the surface of the
diffusion plate.
Refer to "6. "Nozzle Change"
Window" in "Chapter 3 (Vol. 2)"
for the procedure of nozzle storage.
Nozzle U/D Ball Screw (NL Axis)
Every 3 Months Cleaning and Lubrication
(DAPHNE EPONEX GREASE No. 1)
Required Time: 5 minutes
Wipe off the old grease with a rag and
apply a small amount of new grease to the
groove of the ball screw with a syringe.
Use No. 19 (brown) nozzle.
Note
No. 19
Reference
Coupling
Fig. 4A20