4OM-1345-009_w.pdf - 第154页
3-7 AKHEMT -ID Erroe ID Error Name, Description, Cause, and Remedy 400701 Zero Return Beam XY zeroing Error ----- 400702 Zero Return When beam XY (Rear) starting zeroed, the standard mark gap was generated. Please start …

3-6
AKHEMT-ID
Erroe ID Error Name, Description, Cause, and Remedy
400420 Interlock Error
L3 axis (Front) Interlock Detected. Please confi rm the nozzle has not fallen when
you push the beam by the hand.
Confi rm of Path line/Head excess pushing detection.
400421 Interlock Error
L1 axis (Rear) Interlock Detected. Please confi rm the nozzle has not fallen when
you push the beam by the hand.
Confi rm of Path line/Head excess pushing detection.
400422 Interlock Error
L2 axis (Rear) Interlock Detected. Please confi rm the nozzle has not fallen when
you push the beam by the hand.
Confi rm of Path line/Head excess pushing detection.
400423 Interlock Error
L3 axis (Rear) Interlock Detected. Please confi rm the nozzle has not fallen when
you push the beam by the hand.
Confi rm of Path line/Head excess pushing detection.
400425 Interlock Error
An emergency stop switch is pushed.
Please switch on a power supply after canceling an emergency stop switch.
400501 Lightning Surge Warning
Lightning Surge Protector works; L201,L202,L203. Please turn on the load power
supply after resetting error.
-----
400502 Lightning Surge Warning
-----
400503 Lightning Surge Warning
-----
400504 Lightning Surge Warning
-----
400505 Lightning Surge Warning
-----
400601 Servo Alarm
Servo Alarm Detected.
-----
400602 Servo Alarm
All Beam alarm reseting API Error
-----
0609-003
3.1 Safety Devices

3-7
AKHEMT-ID
Erroe ID Error Name, Description, Cause, and Remedy
400701 Zero Return
Beam XY zeroing Error
-----
400702 Zero Return
When beam XY (Rear) starting zeroed, the standard mark gap was generated.
Please start up the power supply.
400703 Zero Return
When beam XY (Front) starting zeroed, the standard mark gap was generated.
Please start up the power supply.
400704 Zero Return
When beam XY (Rear) starting zeroed, recognition error of a standard mark was
generated.
-----
400705 Zero Return
When beam XY (Front) starting zeroed, recognition error of a standard mark was
generated.
-----
400706 Zero Return
The Basis Mark recognition processing at the time of a beam XY (rear) starting
zeroed was not completed within predetermined time.
-----
400707 Zero Return
The Basis Mark recognition processing at the time of a beam XY (front) starting
zeroed was not completed within predetermined time.
-----
400801 Cutter Error
Cutter Alarm Detected (waveform Data setting)
-----
400802 Cutter Error
Cutter Alarm Detected (Zeroing)
-----
400803 Cutter Error
Cutter axis Time Out (Start zero)
-----
400804 Cutter Error
Cutter axis Time Out (Zero)
-----
400805 Cutter Error
Cutter axis zero fi nished
-----
400806 Cutter Error
Cutter axis Alarm Detection (Start Locating)
-----
0609-003
3.1 Safety Devices

3-8
AKHEMT-ID
Erroe ID Error Name, Description, Cause, and Remedy
400836 Cutter Error
Cutter axis Time Out (when locating)
-----
400837 Cutter Error
Cutter axis Alarm Detected (During Locating)
-----
400838 Cutter Error
Cutter axis Alarm Detected (During Locating). The cutter axis zeroing was carried
out.
Please check whether there are any errors in a cutter unit.
400839 Cutter Error
Because main circuit of the cutter axis was OFF or the servo was OFF. The feeder
base descent operation was not able to be done.
Please confi rm the emergency stop and the safety door.
400901 Tray Interlock Error
Main Power Off
-----
400902 Tray Interlock Error
-----
400903 Tray Interlock Error
-----
400904 Tray Interlock Error
-----
400905 Tray Interlock Error
-----
400a01 Head Interlock Error
Head excess pushing detection 3
-----
400a02 Head Interlock Error
Head excess pushing detection 2
-----
400a03 Head Interlock Error
Head excess pushing detection 1
-----
0609-003
3.1 Safety Devices