1-32
AKHEMT-ID
Nozzle Change Cam Face (Lower Side)
Every 3 Months Cleaning and Lubrication
(DAPHNE EPONEX GREASE No. 1)
Required Time: 2 minutes
If a foreign substance adheres to the
nozzle change cam face, remove them with
a pair of tweezers.
Apply grease (0.01 cc) to the cam face with
a syringe.
(a) "0.01 cc" is almost equivalent
to the size of "1005 Chip".
(b)
Use No. 19 (brown) nozzle.
Note
No. 19
Fig. 4A21
0602-001
3.3 Inspection, Cleaning, and Lubrication Spots
1-33
AKHEMT-ID
Cam Followers
Every 3 Months Cleaning and Lubrication
(DAPHNE EPONEX GREASE No. 1)
Required Time: 5 minutes
If foreign substances adhere to the cam
followers, remove them with a pair of
tweezers.
Apply grease (0.01 cc) to the upper sides
of the cam followers with a syringe.
(a) "0.01 cc" is almost equivalent
to the size of "1005 Chip".
(b)
Use No. 19 (brown) nozzle.
Center Spline
Every 3 Months Lubrication
(DAPHNE EPONEX GREASE No. 1)
Required Time: 4 minutes
Apply grease to the groove of the center
spline with a syringe.
Use No. 19 (brown) nozzle.
Note
No. 19
Note
No. 19
Nozzle Change Cam Face (Upper Side)
Every 3 Months Cleaning and Lubrication
(DAPHNE EPONEX GREASE No. 1)
Required Time: 5 minutes
If a foreign substance adheres to the cam
face, remove it with a pair of tweezers.
Apply grease (0.01 cc) to the upper side of
the cam face with a syringe.
(a) "0.01 cc" is almost equivalent
to the size of "1005 Chip".
(b)
Use No. 19 (brown) nozzle.
Note
No. 19
Vacuum Filters (12 places)
Every 3 Months Replacement
Required Time: 30 minutes
Pull up the vacuum filter with the filter
attachment/detachment jig and replace it
with a new one.
Refer to "4.6 Replacement Procedure
of Vacuum Filters" for the
replacement procedure.
Fig. 4A22
0605-002
3.3 Inspection, Cleaning, and Lubrication Spots
1-34
AKHEMT-ID
Vacuum Nozzle
Every 3 Months Inspection
Check the condition of the vacuum nozzle. When
the nozzle end is worn out, replace it with a new
one.
Vacuum Nozzle
Every Week Cleaning
Clean the tapered area of the nozzle with a lens
cleaning cloth.
Store the nozzle in the nozzle stocker (housing)
through window navigations and take out the
nozzle stocker (housing). After that, blow air to
the stocker (housing) to remove dirt and dust.
(a) Do not take out a nozzle from the
head by hand. Otherwise, the
nozzle does not conform to the
nozzle data.
(b) When the nozzle is extremely dirty
or the vacuum suction force
weakens, causing the nozzle to
improperly pick or place components,
it is required to clean the nozzle in the
water with an ultrasonic cleaner.
Do not use anything other than water
for the cleaning.
(a) Refer to "4.1 Cleaning of Vacuum
Nozzles" for details.
(b) Refer to "6. "Nozzle Change" Window"
in "Chapter 3 (Vol. 2)" for the procedure
of nozzle storage.
Notice
Reference
Fig. 4A23
0602-001
3.3 Inspection, Cleaning, and Lubrication Spots