4OM-1345-009_w.pdf - 第159页
3-12 AKHEMT -ID 3.3 Conveyor T able 4C5 Erroe ID Error Name, Description, Cause, and Remedy 420801 Manual transfer error When operation started, error was detected. ----- 420802 Manual transfer error Error was detected w…

3-11
AKHEMT-ID
Erroe ID Error Name, Description, Cause, and Remedy
410306 Pattern Program Error
The error is found in the nozzle candidate number of the conversion pattern
program.
-----
410307 Pattern Program Error
The error is found in the adsorption lane number of the conversion pattern program.
-----
410308 Pattern Program Error
The error is found in the alternation lane number of the comp arrangement data of
the conversion pattern program.
-----
410309 Pattern Program Error
The conversion of the pattern program did not end in prescribed time.
-----
410401 Component Library Data Error
The part library data used by the converted pattern program doesn’t exist.
-----
410402 Component Library Data Error
The use nozzle candidate was not able to exchange nozzles because of the skip
specifi cation.
-----
410501 Nozzle Data Error
The error is found in the head nozzle data of the device system data.
-----
410502 Nozzle Data Error
The error is found in the stocker nozzle data of the device system data.
-----
410601 Data Error
-----
410602 Data Error
Error is found in the AUTO OPN MODE beginning mode setting data.
-----
410701 Program Error
It was a error setting of the sequence data was found.
-----
410702 Program Error
It was a error setting of the polling task was found.
-----
0602-001
3.2 Data

3-12
AKHEMT-ID
3.3 Conveyor
Table 4C5
Erroe ID Error Name, Description, Cause, and Remedy
420801 Manual transfer error
When operation started, error was detected.
-----
420802 Manual transfer error
Error was detected while operating.
-----
420803 Manual transfer error
Operation did not end in prescribed time.
-----
420901 Transfer Error (Others)
Please check the PCB on each conveyer.
-----
421101 Input Buffer Cnvr. Overtime
PCB from inp. Machine was not received.
Please continue the work after checking the PCB on a conveyor.
421102 Input Buffer Cnvr. Overtime
The PCB transport (exhaust) to Cnvr. Positioning1 did not end in prescribed time.
Please continue the work after checking the PCB on a conveyor.
421103 Input Buffer Cnvr. Overtime
The movement to PCB receiving position did not end in prescribed time.
-----
421104 Input Buffer Cnvr. Overtime
The movement to the arrangement position did not end in prescribed time.
-----
421105 Input Buffer Cnvr. Overtime
The reversal positioning operation did not end in prescribed time.
Please continue the work after checking the PCB on a conveyor.
0605-002
3.3 Conveyor

3-12-1
AKHEMT-ID
Erroe ID Error Name, Description, Cause, and Remedy
421201 Input Buffer Cnvr. PCB Detection
PCB’s were at inlet and outlet of cnvr.
-----
421202 Input Buffer Cnvr. PCB Detection
There is no PCB on the conveyer. The PCB fell while moving to the arrangement
position.
Please continue production after checking whether the PCB has fallen around a
conveyor.
421203 Input Buffer Cnvr. PCB Detection
There is a PCB on the conveyer. The substrate was not able to be exhausted.
Please continue the work after checking the PCB on a conveyor.
421204 Input Buffer Cnvr. PCB Detection
There is no PCB on the conveyer. After the PCB carrying in ended, it can not able to
be detected.
Please continue the work after checking the PCB on a conveyor.
421205 Input Buffer Cnvr. PCB Detection
Positioning change operation when beginning to be operated, the PCB was
detected with the entrance sensor. Please remove it.
Please remove the PCB of a conveyor entrance.
421206 Input Buffer Cnvr. PCB Detection
The PCB was detected by the entrance sensor with the PCB was not able to be
transferred.
Please remove the PCB of a conveyor entrance.
421207 Input Buffer Cnvr. PCB Detection
The PCB was detected with the conveyer exit sensor. Please confi rm the PCB on
the conveyer.
Please continue the work after checking the PCB on a conveyor.
421208 Input Buffer Cnvr. PCB Detection
Manual bypass of the PCB was carried out in the state where a PCB is on a
conveyor.
Please remove the PCB carried out by manual bypass. Production can be
continued.
421209 Input Buffer Cnvr. PCB Detection
The PCB was not found in the proper position.
Please remove the PCB on a conveyor. Production can be continued.
0605-001