4OM-1345-009_w.pdf - 第185页

3-35 AKHEMT -ID 3.13 T est T able 4C15 Erroe ID Error Name, Description, Cause, and Remedy 610101 Comp Recog T est The nozzle type data doesn't exist. ----- 610102 Comp Recog T est ----- 610103 Comp Recog T est ----…

100%1 / 233
3-34
AKHEMT-ID
Erroe ID Error Name, Description, Cause, and Remedy
601501 Recog camera light teach
Recog Process error
-----
601601 Comp. Recog. Camera magni cation teach.
Recog Process error
-----
601a01 Linear measure correction re-teach
The linear measure reading is abnormal.
Please con rm whether the nozzle has adhered to the position.
601b01 Automatic teaching
The nozzle is not installed.
Please install the nozzle.
0602-001
3.12 Automatic Teaching
3-35
AKHEMT-ID
3.13 Test
Table 4C15
Erroe ID Error Name, Description, Cause, and Remedy
610101 Comp Recog Test
The nozzle type data doesn't exist.
-----
610102 Comp Recog Test
-----
610103 Comp Recog Test
-----
610104 Comp Recog Test
-----
610105 Comp Recog Test
-----
610106 Comp Recog Test
-----
610107 Comp Recog Test
-----
610108 Comp Recog Test
-----
610109 Comp Recog Test
-----
610201 XY Beam Test
-----
610301 PEC Recog Test
-----
610401 PEC Recog Test
-----
610501 PEC Recog Test
-----
0602-001
3.13 Test
3-36
AKHEMT-ID
3.14 System Error
Table 4C16
Erroe ID Error Name, Description, Cause, and Remedy
FE0101 Auto Control Error
In auto control the operation can’t be continued Error (Refer to syslog)
-----
0602-001
3.14 System Error