4OM-1345-009_w.pdf - 第85页
1-30 AKHEMT -ID W A R N I N G Pay close attention to the cutter blade during the maintenance work. · Lack of attention will result in a hand injury , etc. · Be suretoattachthexingjigtothecutunitduringthe …

1-29
AKHEMT-ID
WARNING
WARNING
Pay close attention to the cutter blade during the maintenance
work.
•
Lack of attention will result in a hand injury, etc.
•
Be sure to attach the fi xing jig to the cut unit during the
maintenance work for safety purposes.
Linear Guides
Every 3 Months Lubrication
(DAPHNE EPONEX GREASE No. 1)
Required Time: 10 minutes
As for the lower groove, put your hand from the cut
waste chute (cover) and apply the grease to the groove.
Tape Guide
Cut Waste Chute (Cover)
When the tape guide is
detached or attached,
be sure to keep the Y-axis
linear scale free of nicks
and scratches.
Notice
Cutter Box
Every 3 Months Cleaning
Required Time: 5 minutes
(1) Remove four screws and detach
the tape guide.
(2) Use the outer hole of the cut unit
fixing jig and attach the jig with
the bent portion being directed
downward.
No. 18
Note
Attachment Position of
Cut Unit Fixing Jig
(3) Clean the area around the linear
guides with a vacuum cleaner.
(1) Remove four screws and detach the tape guide.
(2) Wipe off the old grease with a rag and apply a
small amount of new grease to the grooves
(upper and lower ones) of the linear guides with a
syringe.
Use No. 18 (green) nozzle.
Fig. 4A19-2
0605-002
3.3 Inspection, Cleaning, and Lubrication Spots

1-30
AKHEMT-ID
WARNING
Pay close attention to the cutter blade during the maintenance
work.
·
Lack
of attention will result in a hand injury, etc.
·
Be
suretoattachthexingjigtothecutunitduringthe
maintenance work for safety purposes.
Tape Guide
Flat Ring
Every 3 Months Replacement
(1) Remove four screws and detach the tape guide.
(2) Use the inner holes of the cutter unit fixture with the tape clamp being closed and attach the jig
with the bent portion being directed upward.
Attachment Position of Cutter Unit Fixture Attachment Condition of Replacement Jig
(3) Cut the used flat ring with a cutter on market and detach it.
(4) Attach a new flat ring to the flat ring replacement jig.
(5) Place the flat ring replacement jig on the roller on the oscillating side (outside of the machine),
push down the flat ring, and insert it into the groove of the roller on the oscillating side.
Required Time: 10 minutes
When the tape guide is
detached or attached,
be sure to keep the Y-axis
linear scale free of nicks
and scratches.
Notice
Fig. 4A19-3
CAUTION
Whilecuttingtheatringwithacutteronmarket,handlethe
cutter with care to avoid getting hurt.
0712-003
3.3 Inspection, Cleaning, and Lubrication Spots

1-30-1
AKHEMT-ID
0712-001
3.3 Inspection, Cleaning, and Lubrication Spots
Tape Guide
Fluorine Sheet, Urethane Clamp
Every Year Replacement
(1) Remove four screws and detach the tape guide.
(2) Attach the cutter unit fixture with the bent portion being
directed downward.
Attachment Position of Cutter Unit Fixture
(3) Replace the fluorine sheet and the urethane clamp.
After the fluorine sheet has been replaced, activate the
cutter without the tape threaded through and cut the
fluorine sheet.
Refer to "4.3 Replacement of Fluorine Sheet and Urethane
Clamp" for the replacement procedure.
Required Time: 5 minutes
Reference
Note
Fig. 4A19-4