4OM-1345-009_w.pdf - 第164页
3-16 AKHEMT -ID Erroe ID Error Name, Description, Cause, and Remedy 425102 Output Cnvr . Overtime The PCB transport (exhaust) to output machine did not end in prescribed time. Please continue the work after checking the …

3-15
AKHEMT-ID
Erroe ID Error Name, Description, Cause, and Remedy
422301 Cnvr. Positioning 1 Error
The carrying in operation was not able to begin.
-----
422302 Cnvr. Positioning 1 Error
The error was detected while carrying in was operating.
Please continue the work after checking the PCB on a conveyor.
422303 Cnvr. Positioning 1 Error
The exhaust operation was not able to begin.
-----
422304 Cnvr. Positioning 1 Error
The error was detected while exhaust was operating.
Please continue the work after checking the PCB on a conveyor.
422305 Cnvr. Positioning 1 Error
The error was deected while the backup base was rising.
-----
422306 Cnvr. Positioning 1 Error
The error was detected while the backup base was descending.
-----
422307 Cnvr. Positioning 1 Error
Rise operation of a PCB locate stopper is not completed.
Please check a stopper.
422308 Cnvr. Positioning 1 Error
Downward operation of a PCB locate stopper is not completed.
Please check a stopper.
422309 Cnvr. Positioning 1 Error
The positioning change operation was not able to begin.
-----
422310 Cnvr. Positioning 1 Error
The error was detected while the positioning change was operating.
Please continue the work after checking the PCB on a conveyor.
422311 Cnvr. Positioning 1 Error
The reversal positioning operation was not able to begin.
-----
422312 Cnvr. Positioning 1 Error
The error was detected while the reversal positioning was operating.
Please continue the work after checking the PCB on a conveyor.
0605-002
3.3 Conveyor

3-16
AKHEMT-ID
Erroe ID Error Name, Description, Cause, and Remedy
425102 Output Cnvr. Overtime
The PCB transport (exhaust) to output machine did not end in prescribed time.
Please continue the work after checking the PCB on a conveyor.
425103 Output Cnvr. Overtime
The movement to PCB receiving position did not end in prescribed time.
-----
425104 Output Cnvr. Overtime
The movement to the arrangement position did not end in prescribed time.
-----
425105 Output Cnvr. Overtime
The PCB transport (carry in) from Cnvr. Positioning 1 did not end in prescribed time.
425106 Output Cnvr. Overtime
The reversal positioning operation did not end in prescribed time.
Please continue the work after checking the PCB on a conveyor.
0605-002
3.3 Conveyor

3-17
AKHEMT-ID
Erroe ID Error Name, Description, Cause, and Remedy
425201 Output Cnvr. PCB Detection
PCB’s were at inlet and outlet of cnvr.
Please continue the work after checking the PCB on a conveyor.
425202 Output Cnvr. PCB Detection
There is no PCB on the Cnvr. The PCB fell while moving to the receiving position.
Please continue production after checking whether the PCB has fallen around a
conveyor.
425203 Output Cnvr. PCB Detection
There is no PCB on the Cnvr. The PCB was removed.
-----
425204 Output Cnvr. PCB Detection
There is no PCB on the Cnvr. The PCB could not be discharged.
Please continue the work after checking the PCB on a conveyor.
425205 Output Cnvr. PCB Detection
There is no PCB on the conveyer. After the PCB carrying in ended, it can not able to
be detected.
Please continue the work after checking the PCB on a conveyor.
425206 Output Cnvr. PCB Detection
The PCB was detected by the conveyer entrance sensor.
Please continue the work after checking the PCB on a conveyor.
425207 Output Cnvr. PCB Detection
The PCB was detected with the conveyer exit sensor.
Please confi rm the PCB on the conveyer.
425210 Output Cnvr. PCB Detection
Manual bypass of the PCB was carried out in the state where a PCB is on a
conveyor.
Please remove the PCB carried out manual bypass. Production can be continued.
425211 Output Cnvr. PCB Detection
The PCB was not found in the proper position.
Please remove the PCB on a conveyor. Production can be continued.
425212 Output Cnvr. PCB Detection
Manual bypass of the PCB was carried out.
Please remove the PCB carried out manual bypass. Production can be continued.
0605-002
3.3 Conveyor