Page 7-9 DA T A MODIFICA TION 7 7-4-2 Complete Part Information General parts information including the chip data and extended chip data (only applicable chips) is indicated. 1 . After selecting the chip name of the feed…

100%1 / 102
Page 7-8
Feeder Layout / Stock Data
7-4-1 Occupancy
You can check the occupancy on the feeder table.
For feeder table 1 (on the tape feeder side)
1. After selecting the desired table on
the feeder layout and stock data
screen, press Occupancy .
The rate of the occupied feeder table is dis-
played.
The occupied feeder table including the one
which occupies some pitch in a feeder is
displayed in blue. If data are set not to set the
feeders, the indication becomes red.
For the feeder table 2 (on the tray feeder side)
4H4C-E-OMA07-A01-01
Page 7-9
DATA MODIFICATION
7
7-4-2 Complete Part Information
General parts information including the chip data and extended chip data (only applicable chips) is
indicated.
1. After selecting the chip name of the
feeder layout and stock data screen,
press Complete part info .
When the same parts more than 4 are set in
the stock data, press Next Address to display
the next address by 3 parts.
7-4-3 Angle Definition
The angle definition in picking up and mounting the main chips is described.
1. Press of the feeder layout
and stock data screen.
The style angle and the mount angle have a
common angle definition.
4H4C-E-OMA07-A01-02
Angle
definition
Feeder Layout / Stock Data
Page 7-10
7-5 Chip Data / Tray Data
Chip data
The chip data is checked and modified.
1. Press .
2. After selecting the feeder table, move
the cursor to “Chip name” of the chip
data to be changed with ↑ ↓ → ← ,
and press Change .
Nozzle : Nozzle name
Chip count : Chips per reel
REF : Chip recognition reference
number
4H4C-E-OMA07-A01-05
Feeder layout
Stock data
1
2
3