Page 8-33 TEACHING 8 T eaching the Mount Position 9 . Press UNLOCK + T each start . • The board is carried in to the stage, and moves to the position to be mounted first. 10 . Adjust the lamp value to what is easier to s…

100%1 / 102
Page 8-32
Teaching the Mount Position
5. Set the mounted board.
(It is unnecessary when the board is on the
stage.)
6. When SEQ. No. with a deviated mount
position is recognized, press
Mount data edit .
When SEQ. No. is not known, proceed to step
8.
7. Check the coordinates of the SEQ.
No. with a deviated mount position.
NOTICE
Pressing Call by SEQ changes
numerical keys and makes it
possible to enter numerals. When
the cursor is on the numerals of
the coordinate, pressing not
Call by SEQ but the numeralical
keys changes the numerals of
coordinates.
8. After checking, press .
To the next page
4H4C-EEn-DmMd-001
4H4C-E-OMA08-A03-03
Page 8-33
TEACHING
8
Teaching the Mount Position
9. Press
UNLOCK
+ Teach start .
The board is carried in to the stage, and moves
to the position to be mounted first.
10. Adjust the lamp value to what is
easier to see the screen.
11. When SEQ No. is known,
press Set SEQ to enter that numerals
( No. ).
Move the board to the mounting position of
selected SEQ No.
When SEQ No. is not known,
press
UNLOCK
+ To next SEQ to move the board
to the next coordinates which have the mount
position deviation.
NOTICE
Do not touch the recognition
screen here.
Pressing small red triangle, on
the recognition screen with
UNLOCK
held moves the coordinates, and
then press
UNLOCK
+ Complete to
renew the mount data.
To the next page
4H4C-E-OMA08-A03-04
1
2
Page 8-34
Teaching the Mount Position
12. When the modification is needed,
after checking SEQ No., press the red
triangle, around the recognition
screen holding
UNLOCK
to move the
center of the pattern to the center of
the screen.
13. Press
UNLOCK
+ Complete .
The mount coordinates are renewed.
14. Press and return to the screen
for step 6.
If the data save mode is set to Pattern, this
operation is not necessary.
15. Press Mount data edit on the screen
for step 6 again, and ensure that the
coordinates are renewed, then press
.
16. Press again.
17. Press Yes .
The board is carried out and teaching is fin-
ished.
The production data teaching screen reap-
pears.
4H4C-EEn-DmPtMp-003
4H4C-EEn-DmMd-001
4H4C-E-OMA08-A03-04