OM-1743-005w.pdf - 第103页

7.4.4 Component Discharging Section Discharging Outlet Every week Cleaning Blow the air in the direction of the discharging outlet. (The components are discharged from the opening opposite to this outlet). When any compo…

100%1 / 151
7.4.3 Cover Tape Take-up Section
Tape Guide Roller
Every week Cleaning
Clean it with a rag soaked in alcohol.
Fig. G7
1209-001
7.4 Maintenance Spots
OM-1743
7-8
7.4.4 Component Discharging Section
Discharging Outlet
Every week Cleaning
Blow the air in the direction of
the discharging outlet.
(The components are discharged
from the opening opposite to this
outlet).
When any component is
removed using air-blow,
the components might
scatter around, so perform
this operation paying
attention to the surrounding
condition.
Note
Fig. G8
1209-001
7.4 Maintenance Spots
OM-1743
7-9
7.4.5 Joint Detection Unit
In the case of GD-38080 or GD-38083
Sensor Section
Tape Guide on the Joint Detection Unit
(Only for GD-38080 and GD-38083)
Every week Cleaning
For GD-38080 or GD-38083, lift the cover and
remove any alien substance using the applicator
or bamboo probe.
If any foreign substance is attached
when the tape is passed through,
it might damage the joint detection
sensor or cause a tape feeding error.
Refer to "7.5.4 8 mm Dual Feeder
Joint Detection Unit Sensor Section
Cleaning (For GD-38080, or GD-38083)
for details.
Reference
Notice
Fig. G9
1209-001
7.4 Maintenance Spots
OM-1743
7-10