OM-1743-005w.pdf - 第79页

1209-001 5. Component Pick-up Position Alignment To pick up a component correctly, the component center is aligned with the pick- up position. The component center set position is marked on the suppressor. Also, the pick…

100%1 / 151
1209-001
OM-1743
4-18
1209-001
5. Component Pick-up Position Alignment
To pick up a component correctly, the component center is aligned with the pick-
up position.
The component center set position is marked on the suppressor.
Also, the pick-up position varies with the pitch of the feed.
Notice
If the component center is not aligned with the pick-up position, then the
pick-up cannot proceed correctly.
Reference
Refer to "4.2.4 Minimum Pitch Feed Operation" for the tape feeding operation.
Suppressor
Fig. E1
5. Component Pick-up Position Alignment
OM-1743
5-1
GT-38080, GD-38080
GD-38083
Pick-up Position at 4 mm pitchPick-up Position at 2 mm pitch
Direction of Feed
Pick-up
Position
Pick-up
Position
Direction of Feed
Pick-up
Position
Pick-up
Position
Pick-up Position at 1 mm pitch and 2mm pitch
Fig. E2
1209-001
5. Component Pick-up Position Alignment
OM-1743
5-2