OM-1743-005w.pdf - 第30页

1209-001 OM-1743 1-6

100%1 / 151
1209-001
[12] Cover Tape Outlet Cover
This is the cover on the cover tape housing section.
This cover is opened when the cover tape is taken out from the cover tape
housing section.
[13] Cutter
This cutter cuts off the cover tape taken from the cover tape housing section.
[14] Magnetic Plate
It is attached to the chute section.
Using magnetic force, the component pick-up operation is stabilized.
[15] Magnetic Plate Housing Section
When the Magnetic Plate is not to be used, it is stored in this housing space.
1.2 Name and Function of Each Section
OM-1743
1-5
1209-001
OM-1743
1-6
2. Attachment and Detachment of Tape
2.1 Attachment of Paper or Embossed Tape
Procedure
(1) While gently pressing the end of the suppressor with your nger, press the
lower side of the front hook to lift the suppressor.
Suppressor
Front Hook
Fig. B1
Notice
The suppressor is an important component which affects the pick-
up rate greatly.
If unnecessary stress works on the suppressor, such as dropping
the tape feeder, it might become deformed.
Take the greatest care in handling the suppressor.
Suppressor
8 mm Width Dual Feeder
When the suppressor is lifted to
the point where clicking sound
is heard, the upper section can
be locked.
Fig. B2
1209-001
2. Attachment and Detachment of Tape
OM-1743
2-1