OM-1743-005w.pdf - 第82页

1209-001 6.2. Setting in the Main Machine before Splicing Operation Notice When the splicing operation is to be performed, the splicing setting in the machine body is required. Reference Refer to "4.2.8 Splicing&quo…

100%1 / 151
1209-001
6. Splicing
The taping components can be supplied to the tape feeder without stopping
automatic operation by splicing during operation.
6.1 Preparation of Splicing
When the splicing operation is to be performed, the splicing setting in the machine
body is required before beginning the splicing operation.
The tape cutting jig and splicing tape are required for the splicing operation,
The selection of the splicing tape depends on the tape width for the taping.
Tape Cutting Jig with a Mirror
KJ3-MY045-10 : For a tape of 8 to 32 mm width
Splicing Tape
KYK-M860E-00 : For a tape of 8 mm width
Fig. F1 Tape Cutting Jig and Splicing Tape
Notice
The warranty period of the splicing tape is one year from the time when
the tape is shipped from our company.
Store the splicing tape in the place where the temperature is 30 °C or
less and the sunlight does not hit directly.
When the splicing tape is stored in the place where the temperature is
more than 40 °C or the sunlight hits directly, the adhesive strength of the
splicing tape might be degraded even within the warranty period.
6. Splicing
OM-1743
6-1
1209-001
6.2. Setting in the Main Machine before Splicing Operation
Notice
When the splicing operation is to be performed, the splicing setting in the
machine body is required.
Reference
Refer to "4.2.8 Splicing" in Chapter 1, Volume 2 in the Instruction Manual for
the Main Machine, for the description of the "Splicing" window.
6.2.1 Setting in the Splicing Stop and Warning Mode
Procedure
(1) Press the [Opn. Mode] tab in the "AUTO OPN" window.
(The "Opn. Mode" tab sheet will appear.)
(2) Press the [Opn. Mode] tab and press the [SPL Only] button on the "Opn.
Mode" tab sheet.
(The "Splicing" window will appear.)
Fig. F2 "SPL Only" Window
(3) Select "Enable" in the "Splicing Stop (900 mm)" selection box in the "Stop
Mode" group box.
6.2. Setting in the Main Machine before Splicing Operation
OM-1743
6-2
1209-001
(4) Set the timing to indicate the "Splicing Warning".
Specied with [Tape Length (mm)]
Note
The "Splicing Warning" is not indicated with a remaining tape length of
900 mm or less.
(4.1) Select "Tape Length" in the Warning Mode "90 mm + Condition"
text box.
(4.2) Press the [Count] button.
(The "Count" input window will appear.)
FF3 "Count" Input Window
(4.3) Enter the tape length.
Input Range
: 0 to 9999 mm
(4.4) Press the [Set] button to dene the entered values.
Specied with [PCB Count]
(4.1) Select "PCB Count" in the Warning Mode "90 mm + Condition" text
box.
(4.2) Press the [Count] button.
(The "Count" input window will appear.)
(4.3) Enter the number of PCBs to be produced.
Input Range
: 0 to 9999 PCBs
(4.4) Press the [Set] button to dened the entered values.
(5) Press the [Apply] button.
(The entered values will be applied.
When the [Cancel] button is pressed, the set values are cancelled.)
6.2. Setting in the Main Machine before Splicing Operation
OM-1743
6-3