西门子SIPLACE S-27 HM用户手册.pdf - 第107页
User Manual SIPLAC E S-27 HM 4 Setting up the placement machine Software version SR.503.xx 07/2003 US Edition 4.2 Setting up the pl acement machine 107 4.2 Setting up the placement ma chine Æ Raise the p lacement m achin…

4 Setting up the placement machine User Manual SIPLACE S-27 HM
4.1 Transport dimensions Software version SR.503.xx07/2003 US Edition
106
4.1.1 Transport configuration and transportation
The following components are not installed when the placement machine is delivered from the
factory:
– Keyboards
–Monitors
– Fault indicator lamp and
– Component trolley
Æ Install the dismantled components for commissioning.
Æ Use a fork-lift truck to transport the placement machine with a minimum fork length of
1600 mm.
Æ Attach the fork-lift truck only at the indicated points.
4.1.2 Quality of the foundation
Æ Ensure that
– you set up the placement machine on a firm and non-vibrating foundation.
– the load bearing capacity per unit area of the foundation is greater than 1000 kg/m².
4.1.3 Compressed air supply
– The pressure of the compressed air supply must be 0.55 MPa (5.5 bar) min. The maximum
permitted value is 0.8 MPa (8 bar).
– The compressed air must conform to the specification (see Section 3.4
from page 80).
This can be achieved with
– oil-free compressors, e.g. Atlas, Copco type ZR4
– compressed air washer/driers
– micro-filters, series X, e.g. from Zander
4.1.4 Main power supply
– The power socket must be fused. The fuse ratings are:
3 x 16 A for 3 x 400 VAC / 3 x 208 VAC/3 x 200 VAC 4

User Manual SIPLACE S-27 HM 4 Setting up the placement machine
Software version SR.503.xx 07/2003 US Edition 4.2 Setting up the placement machine
107
4.2 Setting up the placement machine
Æ Raise the placement machine using the fork-lift truck, and adjust the feet until there is a gap of
830 mm between the top edge of the PCB conveyor and the bottom edge of the feet.
Æ Leave a gap of 1 to 3 mm between the PCB conveyors of the placement machine.
Æ Align all the placement machines exactly in line with one another. Use a cord pulled tight to
ensure this.
Æ Adjust each placement machine using a spirit level with an accuracy of 0.02 mm/m.
Æ Lock the feet in position.
Æ Check the placement machine again using the spirit level and correct the settings, if necessary.
CAUTION
Make sure that you remove all the shipping braces from the placement machine. 4
Æ Fit any components that were dismantled for dispatch.
Æ Connect all the electrical and pneumatic lines.
RISK OF DEATH
The electrical connection work MUST be carried out only by appropriately trained and cer-
tified personnel. 4

4 Setting up the placement machine User Manual SIPLACE S-27 HM
4.3 Converting the component trolley for other PCB transport heights Software version SR.503.xx07/2003 US Edition
108
4.3 Converting the component trolley for other PCB
transport heights
4.3.1 Tools
Allen key, set up to 8 mm
4.3.2 Safety instructions
WARNING DANGER OF CRUSHING
Remove all the feeders from the table bed before you change the height of the table on the com-
ponent trolley. Take care during the conversion work because the table bed is very heavy. 4
4
Fig. 4.3 - 1 Converting the component trolley for another PCB transport height
(1) Clamping screws, 4 on each side
(2) Holes in the cross-beam for setting the table height to 830, 900, 930 and 950 mm