User Manual SIPLAC E S-27 HM 4 Setting up the placement machine Software version SR.503.xx 07/2003 US Edition 4.2 Setting up the pl acement machine 107 4.2 Setting up the placement ma chine Æ Raise the p lacement m achin…

100%1 / 222
4 Setting up the placement machine User Manual SIPLACE S-27 HM
4.1 Transport dimensions Software version SR.503.xx07/2003 US Edition
106
4.1.1 Transport configuration and transportation
The following components are not installed when the placement machine is delivered from the
factory:
Keyboards
–Monitors
Fault indicator lamp and
Component trolley
Æ Install the dismantled components for commissioning.
Æ Use a fork-lift truck to transport the placement machine with a minimum fork length of
1600 mm.
Æ Attach the fork-lift truck only at the indicated points.
4.1.2 Quality of the foundation
Æ Ensure that
you set up the placement machine on a firm and non-vibrating foundation.
the load bearing capacity per unit area of the foundation is greater than 1000 kg/m².
4.1.3 Compressed air supply
The pressure of the compressed air supply must be 0.55 MPa (5.5 bar) min. The maximum
permitted value is 0.8 MPa (8 bar).
The compressed air must conform to the specification (see Section 3.4
from page 80).
This can be achieved with
oil-free compressors, e.g. Atlas, Copco type ZR4
compressed air washer/driers
micro-filters, series X, e.g. from Zander
4.1.4 Main power supply
The power socket must be fused. The fuse ratings are:
3 x 16 A for 3 x 400 VAC / 3 x 208 VAC/3 x 200 VAC 4
User Manual SIPLACE S-27 HM 4 Setting up the placement machine
Software version SR.503.xx 07/2003 US Edition 4.2 Setting up the placement machine
107
4.2 Setting up the placement machine
Æ Raise the placement machine using the fork-lift truck, and adjust the feet until there is a gap of
830 mm between the top edge of the PCB conveyor and the bottom edge of the feet.
Æ Leave a gap of 1 to 3 mm between the PCB conveyors of the placement machine.
Æ Align all the placement machines exactly in line with one another. Use a cord pulled tight to
ensure this.
Æ Adjust each placement machine using a spirit level with an accuracy of 0.02 mm/m.
Æ Lock the feet in position.
Æ Check the placement machine again using the spirit level and correct the settings, if necessary.
CAUTION
Make sure that you remove all the shipping braces from the placement machine. 4
Æ Fit any components that were dismantled for dispatch.
Æ Connect all the electrical and pneumatic lines.
RISK OF DEATH
The electrical connection work MUST be carried out only by appropriately trained and cer-
tified personnel. 4
4 Setting up the placement machine User Manual SIPLACE S-27 HM
4.3 Converting the component trolley for other PCB transport heights Software version SR.503.xx07/2003 US Edition
108
4.3 Converting the component trolley for other PCB
transport heights
4.3.1 Tools
Allen key, set up to 8 mm
4.3.2 Safety instructions
WARNING DANGER OF CRUSHING
Remove all the feeders from the table bed before you change the height of the table on the com-
ponent trolley. Take care during the conversion work because the table bed is very heavy. 4
4
Fig. 4.3 - 1 Converting the component trolley for another PCB transport height
(1) Clamping screws, 4 on each side
(2) Holes in the cross-beam for setting the table height to 830, 900, 930 and 950 mm