6.4 Component trolley
6.4.1 Structure
The component trolley consists essentially of a chassis, a component feeder table on which the
feeder is mounted, a communication unit, a tape container and a waste container.
Fig. 6.4 - 1 Component trolley
(1) Component trolley
(2) Communication unit
(3) Control button for raising the component feeder table
(4) Component feeder table
(5) Handle for locking and lowering the component feeder table
(6) Tape container
(7) Waste tape container
NOTE ON OPERATIONAL SAFETY
All component trolleys or matrix tray changers must be docked on the machine in order to oper-
ate it. If they are not, the machine stays in EMERGENCY STOP status. The placement process
is interrupted.

6 Component handling User Manual SIPLACE S-27 HM
6.4 Component trolley Software version SR.503.xx07/2003 US Edition
146
Docking and undocking the component trolley is described in Section 5.9, page 124 onwards.
6.4.2 Tape container
Reels up to 19" in diameter may be used. Insert the spindles into the dividing plates as shown in
Fig. 6.4 - 2
.
PLEASE NOTE 6
We recommend that you use spindles if the tape reel diameter exceeds 7". This will ensure that
the feeders operate reliably. 6
6
Fig. 6.4 - 2 Component trolley with tape container
(1) Component trolley
(2) Spindles
(3) Dividing plate
(4) Tape container

User Manual SIPLACE S-27 HM 6 Component handling
Software version SR.503.xx 07/2003 US Edition 6.4 Component trolley
147
6.4.3 Compressed air supply for bulk case feeder
Bulk case feeders require compressed air to operate. We therefore offer a compressed air supply
for bulk case feeders as an optional extra.
It is easy to fit. The compressed air supply (item 2) is fixed to the component feeder table (item 1)
using three screws DIN 912, M8x20 (Pos. 3). The compressed air supply has retaining clips (item
4) on the back. These secure the bulk case feeder to the component trolley and ensure that the
compressed air supply is working properly.
6
Fig. 6.4 - 3 Compressed air supply for bulk case feeders
(1) Component feeder table
(2) Compressed air supply for bulk case feeders
(3) Screw DIN 912, M8x20