User Manual SIPLAC E S-27 HM 7 Station extensions Software vers ion SR.503.xx 07/ 2003 US Edition 7.1 Nozzle changer for the 12-segm ent Collect&Place head 165 7.1.4 Notes on operation Æ When you fi ll a magazi ne wi…

7 Station extensions User Manual SIPLACE S-27 HM
7.1 Nozzle changer for the 12-segment Collect&Place head Software version SR.503.xx07/2003 US Edition
164
Fig. 7.1 - 2 Magazine and nozzle garages
(1) Positioning fiducial
(2) Locking plate
(3) Nozzle garage
(4) Hole for the parallel pin for centering the magazines
(5) Hole for the parallel pin of the slide mechanism
(6) Slot for the parallel pin for centering the magazines
12 3
4
10 11
12
9
5
6
7
8

User Manual SIPLACE S-27 HM 7 Station extensions
Software version SR.503.xx 07/2003 US Edition 7.1 Nozzle changer for the 12-segment Collect&Place head
165
7.1.4 Notes on operation
Æ When you fill a magazine with a certain nozzle type for the first time, attach an adhesive label
to identify the type.
PLEASE NOTE 7
Only ONE nozzle type must be used in each magazine.
Fill the magazines off the machine and always replace complete magazines. 7
Æ Open the locking plate and place the nozzles in the nozzle garages.
Æ Close the locking plate so that the nozzles cannot drop out of the magazines.
CAUTION 7
Before you fill magazine, make sure that all the nozzles on the Collect&Place head have
been returned to their magazines. 7
Æ Programming the nozzle changer is described in the User manuals for the UNIX line com-
puter and the SIPLACE Pro computer.
PLEASE NOTE 7
Æ Do not allow components to drop onto the magazines. If they do, they could jam the locking
plate.
Æ Do not allow components to drop onto free feeder locations. They will stick to the magnetic
bar. Production may have to be interrupted if the feeders are not placed on the component
table correctly. You should therefore regularly clean the magazines and free locations.

7 Station extensions User Manual SIPLACE S-27 HM
7.1 Nozzle changer for the 12-segment Collect&Place head Software version SR.503.xx07/2003 US Edition
166
7.1.5 Empty the reject bin
The reject bin can hold approx. 50 nozzles in the 9xx nozzle family. To prevent malfunctions in
the placement process, you must empty the reject bin at regular intervals.
Fig. 7.1 - 3 Emptying the reject bin, 12-segment Collect&Place head
7
(1) Remove the reject bin
Æ Pull the reject bin out of its retainer in the direction indicated by the arrow, and lift the bin out
of its holder.
Æ To return the reject bin, push it back into the retainer.